Smart Variable Transmission Data Logger with Paperless Technology

Product Details
Customization: Available
Display: Screen 128*64 DOT Matrix White Screen (LCD)
Weight: 0-100Kg
Still deciding? Get samples of US$ 240/Piece
Order Sample
Shipping & Policy
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment Methods:
visa mastercard discover JCB diners club american express T/T
PIX SPEI OXXO PSE OZOW
  Support payments in USD
Secure payments: Every payment you make on Made-in-China.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.

360° Virtual Tour

Secured Trading Service
Diamond Member Since 2023

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Number of Employees
16
Year of Establishment
2020-06-16
  • Smart Variable Transmission Data Logger with Paperless Technology
  • Smart Variable Transmission Data Logger with Paperless Technology
  • Smart Variable Transmission Data Logger with Paperless Technology
  • Smart Variable Transmission Data Logger with Paperless Technology
  • Smart Variable Transmission Data Logger with Paperless Technology
  • Smart Variable Transmission Data Logger with Paperless Technology
Find Similar Products
  • Overview
  • Product Description
  • Product Parameters
  • Detailed Photos
  • Product Showing
  • Certifications
  • FAQ
Overview

Basic Info.

Model NO.
GL-R2100E
Input Function
Support up to 4-Wire Analog Inputs
Output Function
Power Distribution, Variable Transmission, Relay a
Communication Function
Interface Provide RS232c and RS485, Modbus RTU
Power Supply
220VAC, 50Hz AC; 24VDC (18-36VDC), 12VDC (9-18VDC)
Accuracy
Thermocouple Cold End Comp. Error &Plusmn
Operating Environment1
Temperature 0-50ºC (Avoid Direct Sunlight)
Operating Environment2
Humidity 0-85%R.H. (No Condensation)
Meter Weight
≤1kg
Trademark
Aice Tech
Origin
China
HS Code
9026202000

Product Description

Welcome to Jiangsu Aice Instrument Technology Co., Ltd., your trusted partner in advanced instrumentation solutions.

Product Description

1. INTRODUCTION

Our versatile instrument is designed for a wide range of industrial applications. However, special precautions are necessary for specific uses.
Ensure the device is protected separately when used for specialized applications to maintain optimal performance.
Avoid operating in explosive atmospheres; instead, ensure proper ventilation at the installation site.
Maintain adequate ventilation at the installation site.
Use the rated voltage for the power supply, ensure correct wiring, and proper grounding. Avoid touching the terminals on the back of the device to prevent electric shock.
To avoid electric shock, do not touch the terminals on the back of the device.
For safety, keep the device uncharged during installation, maintenance, and removal.
Ensure the device is not charged during installation, maintenance, and removal for safety.
Shield the device adequately when near power mains, high electric fields, high magnetic fields, and AC contactors.
Take appropriate shielding measures when the device is near power mains, high electric fields, high magnetic fields, and AC contactors.
Implement shielding measures when the device is close to sources like mains power, high electric fields, high magnetic fields, and AC contactors.
To ensure accurate measurements, use the corresponding compensating wire for thermocouple sensors.
Use the appropriate compensating wire for thermocouple sensors to avoid measurement errors.
When using thermal resistance sensors, employ three identical copper conductors with a resistance of less than 10Ω.
For thermal resistance sensors, use three identical copper conductors with resistance below 10Ω.
Ensure the resistance is less than 10Ω when using three identical copper conductors for thermal resistance sensors.
Smart Variable Transmission Data Logger with Paperless Technology

Product Parameters

Display
Screen
128*64 dot matrix white screen liquid crystal display (LCD)
Accuracy
Real-time display: ±0.2% F.S. Trace accuracy: ±0.2% F.S.
(Thermocouple should remove the cold end error)
Processor
Adopts high-performance ARM CORTEX-M3 32-bit RISC core
Input Functions
Input specifications
Supports up to 4 universal analog inputs
Voltage input
0-5V, 1-5V, 0-20MV, 0-100MV
Current input
0-10mA, 4-20mA, 0-20mA
Resistance input
RES (0-400Ω)
Thermistor
PT100, CU50, G53, CU100, BA1, BA2
Thermocouple
s, b, k, t, r, e, n, j
Radiation Pyrometer
F1, F2
Tungsten Rhenium
WRE3-25, WRE5-26
Note
Other input signals (e.g. 0-10V) or index numbers (e.g. PT1000) must be specified when ordering
Output Functions
Distribution output
Supports 1 channel for transmitter centralized power distribution +24VDC, power distribution <60mA
Transformer output
Support up to 2 channels of 4-20mA standard current transducer output, 500Ω load capacity (maximum), convenient for display
instrument or DCS/PLC acquisition, realize the long distance transmission of signal
Relay alarm output
Support up to 4 channels relay alarm output, contact capacity 3A@250VAC / 3A@30VDC, can be configured upper limit, upper limit,
lower limit, lower limit alarm.
Communication Function
Communication interface
RS232C and RS485 communication interface for user to choose, support MODBUS RTU protocol, baud rate (1200, 4800, 9600, 19200,
38400, 57600)
Printing interface
RS232C direct connection to micro printer, baud rate 1200
Power supply
220VAC, 50HZ AC power supply, support 24VDC (18-36VDC), support 12VDC (9-18VDC), Note: DC power supply should be specified when
ordering.
Accuracy
Thermocouple cold end compensation error ±2ºC
Clock error: 2 seconds / day
Working Environment
Ambient temperature
0-50°C (avoid e.g. direct sunlight)
Ambient humidity
0-85%R.H. (no condensation)
Altitude <2000m (prohibited to work in flammable and corrosive environment)

Detailed Photos

Smart Variable Transmission Data Logger with Paperless TechnologySmart Variable Transmission Data Logger with Paperless TechnologySmart Variable Transmission Data Logger with Paperless Technology


Product Showing

Smart Variable Transmission Data Logger with Paperless TechnologySmart Variable Transmission Data Logger with Paperless TechnologySmart Variable Transmission Data Logger with Paperless TechnologySmart Variable Transmission Data Logger with Paperless Technology


Certifications


Smart Variable Transmission Data Logger with Paperless Technology

Smart Variable Transmission Data Logger with Paperless TechnologySmart Variable Transmission Data Logger with Paperless TechnologySmart Variable Transmission Data Logger with Paperless TechnologySmart Variable Transmission Data Logger with Paperless Technology
FAQ

1. Q: Can I buy any of your product accessories?

A: Yes, most of our accessories are available for purchase. However, some patented designs or items protected by intellectual property rights cannot be sold. For more details, please contact our sales team.
Reach out to our sales team for more details on accessory purchases.

2. Q: Can I be your exclusive distributor?

A: Yes, we welcome exclusive distributors based on annual purchase volumes and a long-term relationship. We seek partners who can build a mutual relationship of trust.
We are looking for partners who can achieve a lasting relationship of trust and collaborate on a long-term basis.

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now