Aice Tech Flow Rate and Total Measurement Submerged Doppler Open Channel Flowmeter

Product Details
Customization: Available
After-sales Service: 1 Year
Warranty: 1 Year
Still deciding? Get samples of US$ 1905/Piece
Request Sample

360° Virtual Tour

Diamond Member Since 2023

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Number of Employees
16
Year of Establishment
2020-06-16
  • Aice Tech Flow Rate and Total Measurement Submerged Doppler Open Channel Flowmeter
  • Aice Tech Flow Rate and Total Measurement Submerged Doppler Open Channel Flowmeter
  • Aice Tech Flow Rate and Total Measurement Submerged Doppler Open Channel Flowmeter
  • Aice Tech Flow Rate and Total Measurement Submerged Doppler Open Channel Flowmeter
  • Aice Tech Flow Rate and Total Measurement Submerged Doppler Open Channel Flowmeter
  • Aice Tech Flow Rate and Total Measurement Submerged Doppler Open Channel Flowmeter
Find Similar Products
  • Overview
  • Product Description
  • Product Parameters
  • Detailed Photos
  • Installation Instructions
  • Certifications
  • FAQ
Overview

Basic Info.

Model NO.
RC-DP-101-C4
Accuracy
±0.6-1%
Main Application
Water, Wastewater
Size
DN100-500
Sensor
Plug-in
Application
Industrial Production
Type
Ultrasonic Flow Meter
Measuring Media
Liquid
Measuring Principle
Acoustics
Measurement Object
Open Channel
Certification
CE, ISO
Flow Rate Range
0~10m/S
Flow Rate Resolution
0.001m/S
Velocity Accuracy
0.001m/S (When Velocity <= 5m/S)
Ultrasonic Level Range
6.5m
Ultrasonic Level Accuracy
0.001m
Ultrasonic Level Resolution
0.0005m
Hydrostatic Level Range
0~10m
Hydrostatic Level Accuracy
±0.1%Fs
Hydrostatic Level Resolution
0.001m
Temperature Range
-20~60ºC
Install
Special Bracket
Material
Metal, POM, Rubber
Protection Class
IP68
Powered by
DC12V/24V
Power Consumption
<90mA During Measurement; <25mA During Sleep
Transport Package
Cartons
Specification
50*25*22CM 3KG
Trademark
Aice Tech
Origin
China
HS Code
9026100000
Production Capacity
5000000/Pieces

Product Description

 

Welcome to Jiangsu Aice Instrument Technology Co., Ltd.

Product Description

 

The Acoustic Doppler Point Flowmeter is a flow detection instrument for rivers, open channels and pipelines. It adopts ultrasonic detection technology, with high measurement accuracy, high stability, low influence by environmental factors, no rotating parts, low maintenance frequency and high working reliability, and is the product of choice for online and portable measurement.

Doppler effect, the frequency difference between transmission and reception and flow velocity to establish a relationship, the time difference between ultrasonic transmission and reception and liquid level to establish a relationship, static pressure level for special working conditions, ambient temperature measurement for correction of the actual speed of ultrasonic propagation.


 
Aice Tech Flow Rate and Total Measurement Submerged Doppler Open Channel Flowmeter
 
Product Parameters
 
  • Flow rate range
    0~10m/s
    Flow rate resolution
    0.001m/s
    Velocity Accuracy
    0.001m/s (when velocity <= 5m/s); 0.02m/s or 0.3% of actual peak velocity (whichever is greater) (when velocity > 5m/s)
    Ultrasonic Level Range
    6.5m
    Ultrasonic Level Accuracy
    0.001m
    Ultrasonic level resolution
    0.0005m
    Hydrostatic level range
    0~10m
    Hydrostatic level accuracy
    ±0.1%FS
    Hydrostatic level resolution
    0.001m
    Temperature range
    -20~60ºC
    Install
    Special bracket
    material
    Metal, POM, Rubber
    Protection class
    IP68
    Powered by
    DC12V/24V
    Power consumption
    <90mA during measurement; <25mA during sleep
    Communication Interface
    RS485, Modbus
    Working temperature
    -20~60ºC
    Work pressure
    Max 6Bar
     
 
 
Detailed Photos
 
Aice Tech Flow Rate and Total Measurement Submerged Doppler Open Channel Flowmeter
Aice Tech Flow Rate and Total Measurement Submerged Doppler Open Channel Flowmeter
Installation Instructions
 
Doppler effect, the frequency difference between transmission and reception and flow velocity to establish a relationship, the time difference between ultrasonic transmission and reception and liquid level to establish a relationship, static pressure level for special working conditions, ambient temperature measurement for correction of the actual speed of ultrasonic propagation.
1.1.2 Characteristics
Industrial stainless steel and industrial plastic material, waterproof, anti-corrosion, strong and durable
No wearing parts, less maintenance and low cost of use
High resolution, high measurement accuracy
The service life of the sensor is more than 5 years
Not afraid of the interference of chemical reagents, liquid viscosity and other factors
18-key keypad operation, Chinese and English menus
4~20mA isolated current output
Isolated RS485 (Modbus RTU) communication interface
Upper and lower limit alarm function relay output

2.1 Installation instructions
To ensure the safety of the installer and the proper operation of the sensor, please install in the following order:
1) Mount the meter box and sensor bracket.
2) Fit the meter head into the meter case and secure it.
3) Mounting the sensor.
4) Electrical connection.

2.2 Mainframe installation
The mainframe has two types of installation, embedded and wall-mounted.
1) Mainframe external dimensions 176 x 150 x 86mm.

Aice Tech Flow Rate and Total Measurement Submerged Doppler Open Channel Flowmeter
Wall mounting dimensions 167 x 105mm
The product is designed with four quick wall mounting holes, simply fix the screws in accordance with the wall mounting fixing points and then hang the static product on it.
Note: Probe installation when the British line commissioning products in fixed. In order to extend the service life of the instrument, the instrument should be well protected from the sun and water.
Aice Tech Flow Rate and Total Measurement Submerged Doppler Open Channel Flowmeter

2.3 Sensor installation
Precautions:
1)Do not shock the sensor!
2)Do not unscrew the locking wire connector on the sensor when it is installed, as this may cause damage to the sensor!
3)When the sensor is in water, make sure that the water does not freeze, otherwise the sensor may be damaged!
Sensor dimensions as shown:
Aice Tech Flow Rate and Total Measurement Submerged Doppler Open Channel Flowmeter

1) The following criteria need to be followed when selecting a sensor mounting location.
2) The sensor should be mounted at the appropriate location in the process to ensure that representative measurement results are obtained.
3) The sensor should be installed in an easily accessible location to facilitate regular cleaning of the sensor.
4) The sensor should be installed in a location where the process is well mixed and where there is no downtime, which is usually where the sampling point is located.
5) The sensor should be installed near a representative process sampling point, which should be easy for the operator to perform the sampling operation, and the distance between the sensor and the sampling point should not exceed a maximum of 1.5m (5 feet). During calibration and in subsequent use, it is necessary to sample the process to compare instrument readings with laboratory analysis results. Improper sampling operations are a common cause of erroneous comparison results.

2.4 Sensor installation method
The installation method of immersing the sensor in the channel or pipe through the mounting bracket is suitable for general open channels, pipelines and other occasions.
The sensor must be installed on the mounting bracket. Never hang the sensor in the water with the sensor cable. The sensor should be immersed to a depth of not less than 30cm below the water surface, or to the depth normally reached when sampling, and avoid direct exposure to strong light.
1) Choice of installation site
Choose a place where the water flow is smooth to measure.
Where the water flow is not smooth, in most cases turbulent, the flow velocity measured under turbulent conditions is jumpy and unstable, and the error will be large.
2) Requirements for upstream and downstream channels
Under ideal conditions, the flowmeter installation site upstream of the channel width of 10 times the straight channel, downstream of 3 times the straight channel.
Aice Tech Flow Rate and Total Measurement Submerged Doppler Open Channel Flowmeter
The longer the length of the straight upstream channel the better, the smoother the flow and the closer the velocity measurement will be to the actual flow. And this section should not have any obstructions, such as: gates, weirs, etc., to ensure that the front of the sensor flow pattern is smooth and turbulence-free.

 
Certifications

 

 

Aice Tech Flow Rate and Total Measurement Submerged Doppler Open Channel Flowmeter
Aice Tech Flow Rate and Total Measurement Submerged Doppler Open Channel FlowmeterAice Tech Flow Rate and Total Measurement Submerged Doppler Open Channel FlowmeterAice Tech Flow Rate and Total Measurement Submerged Doppler Open Channel Flowmeter
Aice Tech Flow Rate and Total Measurement Submerged Doppler Open Channel Flowmeter
FAQ
 
1. Q: Can I buy any of your product accessories?

A: Yes you can. Most accessories are able to purchase, but in a few cases of patented designs or intellectual property cannot be
sold. More details please reach out with our sales team.

2. Q: Can I be your exclusive distributor?

A: Yes dear. But this depends on your annual purchase volume and long-term relationship. We need business partners who can achieve
a long-term relationship of trust with each other.

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now