• Marine Pressure Transducer Air Pressure Gauge
  • Marine Pressure Transducer Air Pressure Gauge
  • Marine Pressure Transducer Air Pressure Gauge
  • Marine Pressure Transducer Air Pressure Gauge
  • Marine Pressure Transducer Air Pressure Gauge
  • Marine Pressure Transducer Air Pressure Gauge

Marine Pressure Transducer Air Pressure Gauge

Measuring Medium: Gas
Measuring Temperature: -20~50ºC
Measurement Form: Gauge Pressure, Absolute Pressur
Samples:
US$ 9/Piece 1 Piece(Min.Order)
| Order Sample
Customization:
Shipping Cost:

Estimated freight per unit.

about shipping cost and estimated delivery time.
Payment Method: visa mastercard discover JCB diners club american express T/T
  Initial Payment Full Payment
Currency: US$
Return&refunds: You can apply for a refund up to 30 days after receipt of the products.
From payment to delivery, we protect your trading.
Marine Pressure Transducer Air Pressure Gauge pictures & photos
Marine Pressure Transducer Air Pressure Gauge
US $23.8-31.7 / Piece
Min. Order: 1 Piece
Diamond Member Since 2023

Suppliers with verified business licenses

Secured Trading Service
Rating: 5.0/5
Trading Company
  • Overview
  • Product Description
  • Product Parameters
  • Installation Instructions
  • Product Showing
  • Certifications
  • FAQ
Overview

Basic Info.

Model NO.
SAC-PCM-302
Measurement Range
-0.1MPa ~ 0MPa ~ 6MPa
Measurement Accuracy
0.5%F.S
Measurement Stability
±0.2%Fs/Year
Overload Pressure
150%Fs
Operating Temperature
-20~50ºC
Compensation Temperature
-20~50ºC
Working Humidity
95%Rh
Storage Temperature
-40~85ºC
Trademark
Aice Tech
Origin
China
HS Code
9026202000

Product Description

Welcome to Jiangsu Aice Instrument Technology Co., Ltd., your trusted partner in superior instrumentation solutions. Discover the cutting-edge Marine Pressure Transducer Air Pressure Gauge designed to meet the highest standards of accuracy and reliability.

Product Description

1. INTRODUCTION

This advanced protocol adheres to the MODBUS communication standards, utilizing a sub-centralized RTU mode with RS485 half-duplex operational mode. It ensures seamless integration and optimal performance within the MODBUS framework.

Serial port configuration: no parity, 8 data bits, 1 stop bit.
Example: 9600,N,8,1 Explanation: 9600bps transmission speed, no parity bit, 8 data bits, 1 stop bit.
The transmitter is compatible with the following serial baud rates: 1200, 2400, 4800, 9600, 19200, 38400, 57600, and 115200.
CRC checksum polynomial: 0xA001.
In data communication, all processes handle double-byte shaped data. For floating-point numbers, the decimal point must be read to accurately determine the data size.
Marine Pressure Transducer Air Pressure Gauge

Product Parameters

(1) Effortless Data Retrieval: Read Command Format with (03 Function Code) Example
A. Seamless Data Acquisition: Send Read Command Format.
Address Function Code Data start(H) Data start(L) Data number(H) Data number(L) CRC16
(L)
CRC16(H)
0X01 0X03 0X00 0X00 0X00 0X01 0X84 0X0A

B. Receive Accurate Data: Return to Read Data Format - Example
Address Function Code Data length Data(H) Data(L) CRC16
(L)
CRC16(H)
0X01 0X03 0X02 0X00 0X01 0X79 0X84


(2) Precision Control: Example of Writing Command Format with (06 Function Code)
A. Efficient Data Transfer: Send Read Command Format.
Address Function Code Data start(H) Data start(L) Data number(H) Data number(L) CRC16
(L)
CRC16(H)
0X01 0X06 0X00 0X00 0X00 0X02 0X08 0X0B

  1. Reliable Data Feedback: Return to Read Data Format - Example
Address Function Code Data start(H) Data start(L) Data(H) Data(L) CRC16
(L)
CRC16(H)
0X01 0X06 0X00 0X00 0X00 0X02 0X08 0X0B

  1. Exception Response Returns: Handle Errors with Ease
Address Function Code Exception code CRC16(L) CRC16(H)
0X01 0X80+Function Code 0X01(Illegal functions)    
0X02(Illegal data address)    
0X03(Illegal data)    

4. Supported Commands: Comprehensive Guide to Commands and Data Interpretations
Function Code Data start address Data number Data bytes Data range Command Meaning
0x03 Function code to read data
0x03 0x0000 1 2 1-255 Read slave address
0x03 0x0001 1 2
  1. 1200
 
Baud rate reading

0x03 0x0003 1 2
  1. ####
  1. ###.#
  2. ##.##
  3. #.###
The decimal points represent respectively
0-3 decimal places
0x03 0x0002 1 2 0- Mpa
1- Kpa
2- Pa
3- Bar
4- Mbar
5- kg/cm2
6- psi
7- mh2o
8- mmh2o
 
Pressure units
0x03 0x0004 1 2 -32768~32767 Measured output Value
0x03 0x0005 1 2 -32768~32767 Transmitter range zero point
0x03 0x0006 1 2 -32768~32767 Transmitter range full point
0x03 0x000C 1 2 -32768~32767 Zero offset value, factory default is 0
0x06 Function code reading data
0x06 0x0000   2 1-255  
0x06 0x0001   2
  1. 1200
  1. 2400
  2. 4800
  3. 9600
  4. 19200
  5. 38400
  6. 57600
  7. 115200
Modify baud rate
0x06 0x000C   2 -32768~32767 Zero offset value
Pressure output value = calibration measurement value + zero offset value
           
0x06 0x000F   2 0-Save to user area
1-Save to factory area
 
0x06 0x0010   2 1-Return factory parameters  


Installation Instructions



When adjusting the baud rate, the transmitter will respond by echoing the baud rate sent by the host for modification. Once the response is received, the transmitter's baud rate will be updated to the new target value seamlessly.
Upon modifying the address, the transmitter will first reply with its current address. After this confirmation, the transmitter will automatically update to the new address specified.
To save and confirm the factory command, the transmitter will return to its original value, indicating successful acceptance of the host's command.
Note that when restoring factory settings, the parameters saved by the factory might differ from those saved by the user. This means the address, baud rate, and calibration data may vary. Therefore, it is crucial to re-scan the transmitter after restoring factory parameters.
Users are permitted to modify only three specific data points: address, baud rate, and zero offset.
For calibration or change in calibration data, please contact our company for the transmitter's calibration software. Any user attempt to modify calibration data directly will result in the transmitter outputting a command exception code. Utilize our calibration software for any calibration data modifications.
When reading data identified as a floating point number, such as 6.000, the protocol specifies that data is transmitted as an integer. For instance, 6000 is communicated and then calculated as 6.000 by dividing by 10^3. Hence, 6000 divided by 10^3 results in the value 6.000.
Product Showing

Marine Pressure Transducer Air Pressure GaugeMarine Pressure Transducer Air Pressure GaugeMarine Pressure Transducer Air Pressure Gauge


Certifications


Marine Pressure Transducer Air Pressure Gauge

Marine Pressure Transducer Air Pressure GaugeMarine Pressure Transducer Air Pressure GaugeMarine Pressure Transducer Air Pressure GaugeMarine Pressure Transducer Air Pressure Gauge
FAQ

1. Q: Can I buy any of your product accessories?

A: Absolutely! Most of our accessories are available for purchase. However, please note that a few items with patented designs or covered by intellectual property rights might be unavailable.
For more details, please get in touch with our sales team, who will be happy to assist you further.

2. Q: Can I be your exclusive distributor?

A: Yes, indeed! However, exclusivity is contingent upon your annual purchase volume and our long-term relationship. We seek business partners who can establish and maintain a trusted, long-term collaboration with us.
We believe in building relationships founded on mutual trust and shared goals.

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

From payment to delivery, we protect your trading.
Marine Pressure Transducer Air Pressure Gauge pictures & photos
Marine Pressure Transducer Air Pressure Gauge
US $23.8-31.7 / Piece
Min. Order: 1 Piece
Diamond Member Since 2023

Suppliers with verified business licenses

Secured Trading Service
Rating: 5.0/5
Trading Company
Number of Employees
16
Year of Establishment
2020-06-16