• Intelligent Modbus Pressure Transmitter Sensor
  • Intelligent Modbus Pressure Transmitter Sensor
  • Intelligent Modbus Pressure Transmitter Sensor
  • Intelligent Modbus Pressure Transmitter Sensor
  • Intelligent Modbus Pressure Transmitter Sensor
  • Intelligent Modbus Pressure Transmitter Sensor

Intelligent Modbus Pressure Transmitter Sensor

Measuring Medium: Gas
Model Measuring Core: Ceramic Chip
Measuring Temperature: -20~50ºC
Samples:
US$ 9/Piece 1 Piece(Min.Order)
| Order Sample
Customization:
Shipping Cost:

Estimated freight per unit.

about shipping cost and estimated delivery time.
Payment Method: visa mastercard discover JCB diners club american express T/T
  Initial Payment Full Payment
Currency: US$
Return&refunds: You can apply for a refund up to 30 days after receipt of the products.
From payment to delivery, we protect your trading.
Intelligent Modbus Pressure Transmitter Sensor pictures & photos
Intelligent Modbus Pressure Transmitter Sensor
US $23.8-31.7 / Piece
Min. Order: 1 Piece
Diamond Member Since 2023

Suppliers with verified business licenses

Secured Trading Service
Rating: 5.0/5
Trading Company
  • Overview
  • Product Description
  • Product Parameters
  • Installation Instructions
  • Product Showing
  • Certifications
  • FAQ
Overview

Basic Info.

Model NO.
SAC-131WX
Measurement Form
Gauge Pressure, Absolute Pressur
Measurement Range
-0.1MPa ~ 0MPa ~ 6MPa
Measurement Accuracy
0.5%F.S
Measurement Stability
±0.2%Fs/Year
Overload Pressure
150%Fs
Operating Temperature
-20~50ºC
Compensation Temperature
-20~50ºC
Working Humidity
95%Rh
Storage Temperature
-40~85ºC
Trademark
Aice Tech
Origin
China
HS Code
9026202000

Product Description

Welcome to Jiangsu Aice Instrument Technology Co., Ltd., your premier destination for cutting-edge instrumentation solutions. Discover our world-class Intelligent Modbus Pressure Transmitter Sensor, designed to bring precision and reliability to your industrial applications.

Product Description

1. INTRODUCTION

Engineered to perfection, our Intelligent Modbus Pressure Transmitter Sensor strictly adheres to the MODBUS communication protocol. Utilizing the sophisticated sub-centralized RTU mode and operating seamlessly in RS485 half-duplex mode, this transmitter ensures unparalleled precision and reliability.

Serial Port Configuration: No parity, 8 data bits, 1 stop bit.
Example Configuration: 9600, N, 8, 1 - Signifying 9600bps, no parity, 8 data bits, and 1 stop bit.
Supported Serial Baud Rates: 1200, 2400, 4800, 9600, 19200, 38400, 57600, 115200. This extensive range ensures compatibility with various systems, enhancing versatility.
CRC Checksum Polynomial: 0xA001.
Data Communication: All processes are meticulously handled using double-byte shaped data. For floating-point numbers, the decimal point must be read to accurately determine the data value.
Intelligent Modbus Pressure Transmitter Sensor

Product Parameters

(1) Exemplary Read Command Format (03 Function Code)
A. Dispatch Read Command Format.
Address Function Code Data start(H) Data start(L) Data number(H) Data number(L) CRC16
(L)
CRC16(H)
0X01 0X03 0X00 0X00 0X00 0X01 0X84 0X0A

B. Return to Read Data Format: Illustrative Example
Address Function Code Data length Data(H) Data(L) CRC16
(L)
CRC16(H)
0X01 0X03 0X02 0X00 0X01 0X79 0X84


(2) Noteworthy Example of Writing Command Format (06 Function Code)
A. Dispatch Write Command Format.
Address Function Code Data start(H) Data start(L) Data number(H) Data number(L) CRC16
(L)
CRC16(H)
0X01 0X06 0X00 0X00 0X00 0X02 0X08 0X0B

  1. B. Return to Write Data Format: Illustrative Example
Address Function Code Data start(H) Data start(L) Data(H) Data(L) CRC16
(L)
CRC16(H)
0X01 0X06 0X00 0X00 0X00 0X02 0X08 0X0B

  1. Exception Response Returns
Address Function Code Exception code CRC16(L) CRC16(H)
0X01 0X80+Function Code 0X01(Illegal functions)    
0X02(Illegal data address)    
0X03(Illegal data)    

4. Comprehensive List of Supported Commands and Their Corresponding Data Meanings
Function Code Data start address Data number Data bytes Data range Command Meaning
0x03 Function code to read data
0x03 0x0000 1 2 1-255 Read slave address
0x03 0x0001 1 2
  1. 1200
 
Baud rate reading

0x03 0x0003 1 2
  1. ####
  1. ###.#
  2. ##.##
  3. #.###
The decimal points represent respectively
0-3 decimal places
0x03 0x0002 1 2 0- Mpa
1- Kpa
2- Pa
3- Bar
4- Mbar
5- kg/cm2
6- psi
7- mh2o
8- mmh2o
 
Pressure units
0x03 0x0004 1 2 -32768~32767 Measured output Value
0x03 0x0005 1 2 -32768~32767 Transmitter range zero point
0x03 0x0006 1 2 -32768~32767 Transmitter range full point
0x03 0x000C 1 2 -32768~32767 Zero offset value, factory default is 0
0x06 Function code reading data
0x06 0x0000   2 1-255  
0x06 0x0001   2
  1. 1200
  1. 2400
  2. 4800
  3. 9600
  4. 19200
  5. 38400
  6. 57600
  7. 115200
Modify baud rate
0x06 0x000C   2 -32768~32767 Zero offset value
Pressure output value = calibration measurement value + zero offset value
           
0x06 0x000F   2 0-Save to user area
1-Save to factory area
 
0x06 0x0010   2 1-Return factory parameters  


Installation Instructions



When modifying the baud rate, the transmitter will respond with the current baud rate delivered by the host. Following this acknowledgment, the transmitter's baud rate will seamlessly transition to the newly specified target value.
Upon modifying the address, the transmitter will initially reply with the pre-modification address. After this confirmation, the transmitter’s address will be promptly updated to reflect the new configuration.
Executing the 'Save and Reply' factory command will yield the original preset value, signifying that the transmitter has successfully accepted and processed the host command.
When restoring factory settings, please be aware that factory-saved parameters may differ from user-defined ones. Consequently, addresses, baud rates, and calibration data may vary. Hence, a thorough search of the transmitter is essential after resetting to factory parameters.
Users are permitted to modify only three parameters: address, baud rate, and zero offset. These elements are crucial for optimal transmitter performance.
For calibration adjustments or changes to calibration data, please contact our company for the appropriate calibration software. Unauthorized user commands to alter calibration data will trigger a command exception code from the transmitter. Use the dedicated calibration software for any calibration modifications.
In instances where the data to be read is a floating point number (e.g., 6.000), but protocol communication defines it as an integer format (e.g., 6000), the data is read as 6000. The decimal point placement converts it back to the floating point number. For instance, with a decimal precision of 3, the calculation is 6000 / 10^3, resulting in the value 6.000.
Product Showing

Intelligent Modbus Pressure Transmitter SensorIntelligent Modbus Pressure Transmitter SensorIntelligent Modbus Pressure Transmitter Sensor


Certifications


Intelligent Modbus Pressure Transmitter Sensor

Intelligent Modbus Pressure Transmitter SensorIntelligent Modbus Pressure Transmitter SensorIntelligent Modbus Pressure Transmitter SensorIntelligent Modbus Pressure Transmitter Sensor
FAQ

1. Q: Can I buy any of your product accessories?

A: Absolutely! Most of our accessories are available for purchase. However, certain items with patented designs or intellectual properties may not be available.
For more detailed information, please contact our sales team.

2. Q: Can I be your exclusive distributor?

A: Certainly! Becoming an exclusive distributor depends on your annual purchase volume and our long-term business relationship. We seek partners who can build a trusting, long-term relationship with us.

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

From payment to delivery, we protect your trading.
Intelligent Modbus Pressure Transmitter Sensor pictures & photos
Intelligent Modbus Pressure Transmitter Sensor
US $23.8-31.7 / Piece
Min. Order: 1 Piece
Diamond Member Since 2023

Suppliers with verified business licenses

Secured Trading Service
Rating: 5.0/5
Trading Company
Number of Employees
16
Year of Establishment
2020-06-16