Storage slot installation dimensions, examples and precautions:
1. During installation, the switch can be installed at an angle of 15-20 degrees
horizontally downward to reduce the impact of materials and the occurrence of
hanging materials.
2. It should be possible to be far away from the inlet of the barrel during installation to
avoid material impact and false alarms. If it is unavoidable, a partition must be
installed between the feed inlet and the material level for protection.
3. The cable inlet of the junction box must face down, and the fixing nut of the power
cable inlet must be locked.
4. When the staff is working in the bucket, it is strictly forbidden to use the vibrator to
climb or hang any ropes and objects.
Terminal description:
Relay wiring (brown-power positive, blue-power negative, black-NO white-COM
gray-NC)
PNP output- (brown-power positive, blue-power negative, blue+gray PNP)
NPN output- (brown-power positive, blue-power negative, brown+black NPN)
I.operation declaration:
1. Put the fork body into the measured object and determine the alarm position of the
fork body long press "SET" button or close "SET" with a magnet for 3 seconds, the
setting is complete.
II.special explanation:
1. This sound fork has a self-inspection function. On the one hand, it is to overcome
the vibration absorption phenomenon after the fork body is installed on the bucket
wall, and on the other hand, it is to prevent miscellaneous interference and avoid
misaction.
III. The factory setting value of the product is the density of water (1g / cm ³), as the
benchmark for state switching. When the density to be measured is greater than or
equal to 1g / cm ³, it can be used normally without re-learning.When the density to be
measured is less than 1g / cm ³.
service voltage |
19…60VDC 50/60Hz |
switching time |
About 2 seconds when covered with the medium, and about 3 seconds when the medium is free |
ambient temperature |
-40…+80ºC |
Storage temperature |
-40…+85ºC |
medium temperature |
-40…+150ºC |
on-stream pressure |
-1…+40bar |
Substances tested |
Powder and particles =10mm, with a density> 0.1g / cm ³ |
|
Liquid, viscosity = 10,000 m m2/s, density> 0.7g / cm ³ |
attended mode |
G1-N11* |
Electrical interface |
M12 P1.0 Connector |
Shell material |
Stainless steel S304 |
Fork material Fork material |
Stainless steel S304 / stainless steel S316 |
Output mode is Output |
relay output, Negative numbers were AC250V / 4A, and DC60V / 4A |
|
Collector open circuit (NPN) output, with a negative number of 400mA |
|
Collector open circuit (PNP) output, with a negative number of 400mA |
power dissipation |
0.25W 1.5W AC for DC supply |