Welcome to Jiangsu Aice Instrument Technology Co., Ltd., where innovation meets precision.
Pseudolaric acid: Three-Phase AC Transmitter
Installation: Secure via flat screw fixing.
Primary rated current options: 1A, 5A, 10A, 20A, 50A, 80A, 100A, 150A, 200A, 300A, 400A options available.
Primary edge measurement range: Spanning from 2A to 450A.
Rated Auxiliary Output: Choose from 1v, 10v, DC0-20mA, DC4-20mA, or user-specified configurations.
Auxiliary power: Available in DC12V or DC24V options.
Load capacity: Voltage output supports 5mA; Current output accommodates 6V with an accuracy of 0.5%.
Overload capacity: Endures up to 30 times the nominal input.
Isolated Withstand Voltage: Tested up to 2.5kV/50Hz for 1 minute.
Lossy voltage: <10mV
Temperature drift: <500PPMC
Linearity: Remarkably precise at 0.1%.
Bandwidth: Ranges from 20 to 5KHz.
Overload capacity: <15mA + output current
Response time: <200mS
Operating temperature: Efficiently operates between -10°C and 70°C.
Storage temperature: Safely stored between -25°C and 85°C.