Industrial Pressure Transmitter with Modbus Protocol

Measuring Medium: Gas
Model Measuring Core: Ceramic Chip
Measuring Temperature: -20~50ºC
Samples:
US$ 9/Piece 1 Piece(Min.Order)
| Order Sample
Customization:
Shipping Cost:

Estimated freight per unit.

about shipping cost and estimated delivery time.
Payment Method: visa mastercard discover JCB diners club american express T/T
  Initial Payment Full Payment
Currency: US$
Return&refunds: You can apply for a refund up to 30 days after receipt of the products.
From payment to delivery, we protect your trading.
Industrial Pressure Transmitter with Modbus Protocol pictures & photos
Industrial Pressure Transmitter with Modbus Protocol
US $23.8-31.7 / Piece
Min. Order: 1 Piece
Diamond Member Since 2023

Suppliers with verified business licenses

Secured Trading Service
Rating: 5.0/5
Trading Company
  • Overview
  • Product Description
  • Product Parameters
  • Installation Instructions
  • Product Showing
  • Certifications
  • FAQ
Overview

Basic Info.

Model NO.
SAC-131WX
Measurement Form
Gauge Pressure, Absolute Pressur
Measurement Range
-0.1MPa ~ 0MPa ~ 6MPa
Measurement Accuracy
0.5%F.S
Measurement Stability
±0.2%Fs/Year
Overload Pressure
150%Fs
Operating Temperature
-20~50ºC
Compensation Temperature
-20~50ºC
Working Humidity
95%Rh
Storage Temperature
-40~85ºC
Trademark
Aice Tech
Origin
China
HS Code
9026202000

Product Description

Welcome to Jiangsu Aice Instrument Technology Co., Ltd., where innovation meets precision. Explore our state-of-the-art solutions designed to meet your industrial needs.

Product Description

1.INTRODUCTION

Our Industrial Pressure Transmitter seamlessly integrates with the MODBUS communication protocol, adopting a sub-centralized RTU mode and employing the RS485 half-duplex working mode within the MODBUS framework.

Serial Port Configuration: No parity, 8 data bits, and 1 stop bit.
Example Configuration: 9600,N,8,1 - This signifies a baud rate of 9600bps, no parity, 8 data bits, and 1 stop bit.
Supported Serial Baud Rates include: 1200, 2400, 4800, 9600, 19200, 38400, 57600, and 115200.
CRC Checksum Polynomial: 0xA001.
Data communication adheres to a double-byte data format. For floating-point numbers, it is essential to read the decimal point to ascertain the data's magnitude accurately.
Industrial Pressure Transmitter with Modbus Protocol

Product Parameters

(1) Example of Read Command Format (03 Function Code)
A. Sending the Read Command Format:
Address Function Code Data start(H) Data start(L) Data number(H) Data number(L) CRC16
(L)
CRC16(H)
0X01 0X03 0X00 0X00 0X00 0X01 0X84 0X0A

B. Example of Returned Read Data Format:
Address Function Code Data length Data(H) Data(L) CRC16
(L)
CRC16(H)
0X01 0X03 0X02 0X00 0X01 0X79 0X84


(2) Example of Writing Command Format (06 Function Code)
A. Sending the Write Command Format:
Address Function Code Data start(H) Data start(L) Data number(H) Data number(L) CRC16
(L)
CRC16(H)
0X01 0X06 0X00 0X00 0X00 0X02 0X08 0X0B

  1. B. Example of Returned Write Data Format:
Address Function Code Data start(H) Data start(L) Data(H) Data(L) CRC16
(L)
CRC16(H)
0X01 0X06 0X00 0X00 0X00 0X02 0X08 0X0B

  1. Exception Response Returns:
Address Function Code Exception code CRC16(L) CRC16(H)
0X01 0X80+Function Code 0X01(Illegal functions)    
0X02(Illegal data address)    
0X03(Illegal data)    

4. Supported Commands and Their Meanings with Corresponding Data:
Function Code Data start address Data number Data bytes Data range Command Meaning
0x03 Function code to read data
0x03 0x0000 1 2 1-255 Read slave address
0x03 0x0001 1 2
  1. 1200
 
Baud rate reading

0x03 0x0003 1 2
  1. ####
  1. ###.#
  2. ##.##
  3. #.###
The decimal points represent respectively
0-3 decimal places
0x03 0x0002 1 2 0- Mpa
1- Kpa
2- Pa
3- Bar
4- Mbar
5- kg/cm2
6- psi
7- mh2o
8- mmh2o
 
Pressure units
0x03 0x0004 1 2 -32768~32767 Measured output Value
0x03 0x0005 1 2 -32768~32767 Transmitter range zero point
0x03 0x0006 1 2 -32768~32767 Transmitter range full point
0x03 0x000C 1 2 -32768~32767 Zero offset value, factory default is 0
0x06 Function code reading data
0x06 0x0000   2 1-255  
0x06 0x0001   2
  1. 1200
  1. 2400
  2. 4800
  3. 9600
  4. 19200
  5. 38400
  6. 57600
  7. 115200
Modify baud rate
0x06 0x000C   2 -32768~32767 Zero offset value
Pressure output value = calibration measurement value + zero offset value
           
0x06 0x000F   2 0-Save to user area
1-Save to factory area
 
0x06 0x0010   2 1-Return factory parameters  


Installation Instructions



When modifying the baud rate, the transmitter will respond with the new baud rate value specified by the host. Once this confirmation reply is sent, the transmitter's baud rate will seamlessly update to the desired setting.
Upon modifying the address, the transmitter will first acknowledge the current address prior to alteration. Following this acknowledgment, the transmitter's address will be updated automatically to the new value.
Executing the 'Save and Reply' factory command will return the original set values, confirming that the transmitter has successfully received and accepted the host's command.
When restoring factory settings, please be aware that the factory defaults may differ from user-defined settings. Consequently, parameters such as address, baud rate, and calibration data might change. It's essential to re-scan the transmitter to recognize these new parameters post-restoration.
Users are permitted to modify only three specific data points: address, baud rate, and zero offset.
For calibration or modification of calibration data, please contact our company to obtain the transmitter's calibration software. Unauthorized attempts to change calibration data via user commands will result in the transmitter outputting an exception code. Always use our recommended calibration software for such adjustments.
If the data you need to read is in floating point format (e.g., 6.000), but the protocol indicates it should be communicated as integer data, you will receive it as 6000. To convert this to the correct format, apply the appropriate decimal point shift. For instance, if the decimal point is 3, you would calculate 6000/10^3 to get 6.000.
Product Showing

Industrial Pressure Transmitter with Modbus ProtocolIndustrial Pressure Transmitter with Modbus ProtocolIndustrial Pressure Transmitter with Modbus Protocol


Certifications


Industrial Pressure Transmitter with Modbus Protocol

Industrial Pressure Transmitter with Modbus ProtocolIndustrial Pressure Transmitter with Modbus ProtocolIndustrial Pressure Transmitter with Modbus ProtocolIndustrial Pressure Transmitter with Modbus Protocol
FAQ

1. Q: Can I buy any of your product accessories?

A: Absolutely! Many of our product accessories are available for purchase. However, please note that a few items, due to their patented designs or intellectual property constraints, are not available for sale.
For further details, please contact our sales team.

2. Q: Can I be your exclusive distributor?

A: Certainly! However, this is contingent upon your annual purchase volume and our long-term business relationship. We seek partners who can establish a dependable, long-term relationship with us.
We look forward to fostering a mutually beneficial partnership built on trust.

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

From payment to delivery, we protect your trading.
Industrial Pressure Transmitter with Modbus Protocol pictures & photos
Industrial Pressure Transmitter with Modbus Protocol
US $23.8-31.7 / Piece
Min. Order: 1 Piece