Modbus Temperature Measuring Pressure Transmitter

Measuring Medium: Gas
Model Measuring Core: Ceramic Chip
Measuring Temperature: -20~50ºC
Samples:
US$ 9/Piece 1 Piece(Min.Order)
| Order Sample
Customization:
Shipping Cost:

Estimated freight per unit.

about shipping cost and estimated delivery time.
Payment Method: visa mastercard discover JCB diners club american express T/T
  Initial Payment Full Payment
Currency: US$
Return&refunds: You can apply for a refund up to 30 days after receipt of the products.
From payment to delivery, we protect your trading.
Modbus Temperature Measuring Pressure Transmitter pictures & photos
Modbus Temperature Measuring Pressure Transmitter
US $23.8-31.7 / Piece
Min. Order: 1 Piece
Diamond Member Since 2023

Suppliers with verified business licenses

Secured Trading Service
Rating: 5.0/5
Trading Company
  • Overview
  • Product Description
  • Product Parameters
  • Installation Instructions
  • Product Showing
  • Certifications
  • FAQ
Overview

Basic Info.

Model NO.
SAC-131WX
Measurement Form
Gauge Pressure, Absolute Pressur
Measurement Range
-0.1MPa ~ 0MPa ~ 6MPa
Measurement Accuracy
0.5%F.S
Measurement Stability
±0.2%Fs/Year
Overload Pressure
150%Fs
Operating Temperature
-20~50ºC
Compensation Temperature
-20~50ºC
Working Humidity
95%Rh
Storage Temperature
-40~85ºC
Trademark
Aice Tech
Origin
China
HS Code
9026202000

Product Description

Welcome to Jiangsu Aice Instrument Technology Co., Ltd., where precision meets innovation. We are dedicated to providing state-of-the-art solutions like our Modbus Temperature Measuring Pressure Transmitter, ensuring unparalleled accuracy and reliability for all your instrumentation needs.

Product Description

1. INTRODUCTION

This state-of-the-art product adheres meticulously to the MODBUS communication protocol, employing the sub-centralized RTU mode and RS485 half-duplex working mode for seamless integration and reliable performance.

Serial port configuration: no parity, 8 data bits, 1 stop bit.
Example: 9600, N, 8, 1 Explanation: 9600 bps, no parity, 8 data bits, 1 stop bit.
Our transmitter is versatile, supporting a wide range of serial baud rates: 1200, 2400, 4800, 9600, 19200, 38400, 57600, and 115200.
CRC checksum polynomial: 0xA001.
Data communication processes are meticulously handled in double-byte format. For floating-point data, ensure you read the decimal point accurately to determine precise data measurements.
Modbus Temperature Measuring Pressure Transmitter

Product Parameters

(1) Exemplary Read Command Format (03 Function Code)
A. Initiate the Read Command Format with Confidence.
Address Function Code Data start(H) Data start(L) Data number(H) Data number(L) CRC16
(L)
CRC16(H)
0X01 0X03 0X00 0X00 0X00 0X01 0X84 0X0A

B. Receive and Decipher the Read Data Format: An Example
Address Function Code Data length Data(H) Data(L) CRC16
(L)
CRC16(H)
0X01 0X03 0X02 0X00 0X01 0X79 0X84


(2) Illustrative Example of Writing Command Format (06 Function Code)
A. Masterfully Send the Read Command Format.
Address Function Code Data start(H) Data start(L) Data number(H) Data number(L) CRC16
(L)
CRC16(H)
0X01 0X06 0X00 0X00 0X00 0X02 0X08 0X0B

  1. Effortlessly Return and Interpret the Read Data Format: Example
Address Function Code Data start(H) Data start(L) Data(H) Data(L) CRC16
(L)
CRC16(H)
0X01 0X06 0X00 0X00 0X00 0X02 0X08 0X0B

  1. Exception Response Handling with Precision
Address Function Code Exception code CRC16(L) CRC16(H)
0X01 0X80+Function Code 0X01(Illegal functions)    
0X02(Illegal data address)    
0X03(Illegal data)    

4. Comprehensive Guide to Supported Commands and Their Meaning
Function Code Data start address Data number Data bytes Data range Command Meaning
0x03 Function code to read data
0x03 0x0000 1 2 1-255 Read slave address
0x03 0x0001 1 2
  1. 1200
 
Baud rate reading

0x03 0x0003 1 2
  1. ####
  1. ###.#
  2. ##.##
  3. #.###
The decimal points represent respectively
0-3 decimal places
0x03 0x0002 1 2 0- Mpa
1- Kpa
2- Pa
3- Bar
4- Mbar
5- kg/cm2
6- psi
7- mh2o
8- mmh2o
 
Pressure units
0x03 0x0004 1 2 -32768~32767 Measured output Value
0x03 0x0005 1 2 -32768~32767 Transmitter range zero point
0x03 0x0006 1 2 -32768~32767 Transmitter range full point
0x03 0x000C 1 2 -32768~32767 Zero offset value, factory default is 0
0x06 Function code reading data
0x06 0x0000   2 1-255  
0x06 0x0001   2
  1. 1200
  1. 2400
  2. 4800
  3. 9600
  4. 19200
  5. 38400
  6. 57600
  7. 115200
Modify baud rate
0x06 0x000C   2 -32768~32767 Zero offset value
Pressure output value = calibration measurement value + zero offset value
           
0x06 0x000F   2 0-Save to user area
1-Save to factory area
 
0x06 0x0010   2 1-Return factory parameters  


Installation Instructions



When modifying the baud rate, the transmitter will respond with the host-sent baud rate, updating the transmitter's baud rate to the new target value after confirmation.
Upon modifying the address, the transmitter will first reply with the pre-modified address and then automatically update its address to the new specified value.
Issuing the factory save and reply command returns the original value, indicating the transmitter has successfully received and accepted the host's command.
Important: Restoring factory data means factory-saved parameters may differ from user-saved ones. Consequently, address, baud rate, and calibration data could change. Therefore, you must re-scan the transmitter after restoring factory settings.
Users are permitted to modify only three specific data points: address, baud rate, and zero offset.
For calibration or modification of calibration data, please contact our company to obtain the necessary calibration software. Unauthorized modification attempts by users will result in a command exception code being output by the transmitter. Always use our official calibration software for such tasks.
For data read as a floating point number, e.g., 6.000, the protocol may communicate it as an integer (6000). The decimal point is then used to interpret this—if the decimal point is 3, then 6000/10^3 equals 6.000.
Product Showing

Modbus Temperature Measuring Pressure TransmitterModbus Temperature Measuring Pressure TransmitterModbus Temperature Measuring Pressure Transmitter


Certifications


Modbus Temperature Measuring Pressure Transmitter

Modbus Temperature Measuring Pressure TransmitterModbus Temperature Measuring Pressure TransmitterModbus Temperature Measuring Pressure TransmitterModbus Temperature Measuring Pressure Transmitter
FAQ

1. Q: Can I purchase any of your product accessories directly?

A: Absolutely! You can purchase most accessories directly from us. However, please note that certain accessories involving patented designs or intellectual property may not be available for direct purchase.
For more detailed information, please contact our dedicated sales team.

2. Q: Is it possible for me to become your exclusive distributor?

A: Yes, you can! However, this opportunity is contingent upon your annual purchase volume and our mutual long-term relationship. We are seeking business partners who are committed to building a sustainable and trustworthy partnership.

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

From payment to delivery, we protect your trading.
Modbus Temperature Measuring Pressure Transmitter pictures & photos
Modbus Temperature Measuring Pressure Transmitter
US $23.8-31.7 / Piece
Min. Order: 1 Piece
Diamond Member Since 2023

Suppliers with verified business licenses

Secured Trading Service
Rating: 5.0/5
Trading Company
Number of Employees
16
Year of Establishment
2020-06-16