Display: Screen 128*64 DOT Matrix White Screen (LCD)
Weight: 0-100Kg
Processor: High-Performance Arm Cortex-M3 32-Bit Risc Core
Samples:
US$ 240/Piece 1 Piece(Min.Order)
| Order Sample
Customization:
Shipping Cost:

Estimated freight per unit.

about shipping cost and estimated delivery time.
Payment Method: visa mastercard discover JCB diners club american express T/T
  Initial Payment Full Payment
Currency: US$
Return&refunds: You can apply for a refund up to 30 days after receipt of the products.
From payment to delivery, we protect your trading.
Analog Inputs Paperless Recorder Control Unit pictures & photos
Analog Inputs Paperless Recorder Control Unit
US $108-240 / Piece
Min. Order: 1 Piece
Diamond Member Since 2023

Suppliers with verified business licenses

Secured Trading Service
Rating: 5.0/5
Trading Company
  • Overview
  • Product Description
  • Product Parameters
  • Detailed Photos
  • Product Showing
  • Certifications
  • FAQ
Overview

Basic Info.

Model NO.
GL-R2100E
Input Function
Support up to 4-Wire Analog Inputs
Output Function
Power Distribution, Variable Transmission, Relay a
Communication Function
Interface Provide RS232c and RS485, Modbus RTU
Power Supply
220VAC, 50Hz AC; 24VDC (18-36VDC), 12VDC (9-18VDC)
Accuracy
Thermocouple Cold End Comp. Error &Plusmn
Operating Environment1
Temperature 0-50ºC (Avoid Direct Sunlight)
Operating Environment2
Humidity 0-85%R.H. (No Condensation)
Meter Weight
≤1kg
Trademark
Aice Tech
Origin
China
HS Code
9026202000

Product Description

Welcome to Jiangsu Aice Instrument Technology Co., Ltd., where innovation meets precision in instrumentation technology.

Product Description

1. INTRODUCTION

Our Analog Inputs Paperless Recorder Control Unit is designed for versatility in general industrial applications. However, it is crucial to
ensure the device is properly protected in specialized use scenarios. Avoid operating in explosive atmospheres and maintain adequate
ventilation at the installation site to ensure optimal performance and safety.
ventilation.
Always use the rated voltage power supply, ensure correct wiring, and proper grounding to prevent mishaps. Avoid touching the terminals
on the back of the device to prevent electric shocks.
In order to ensure safety, make sure the device is not charged during installation, maintenance, or removal.
To ensure safety, disconnect power during installation, maintenance, and removal processes.
maintenance, and removal.
Shield the device appropriately if it is near mains power sources, high electric fields, high magnetic fields, or AC contactors to
prevent measurement errors and ensure accurate performance.
fields, and AC contactors.
To avoid measurement inaccuracies when using a thermocouple sensor, always use the corresponding compensating wire. For thermal
resistance sensors, employ three equal copper conductors with a resistance of less than 10Ω.
resistance sensors, use three identical copper conductors with a resistance less than 10Ω.
copper conductors with a resistance of less than 10Ω.
Analog Inputs Paperless Recorder Control Unit

Product Parameters

Display
Screen
128*64 dot matrix white screen liquid crystal display (LCD)
Accuracy
Real-time display: ±0.2% F.S. Trace accuracy: ±0.2% F.S.
(Thermocouple should remove the cold end error)
Processor
Adopts high-performance ARM CORTEX-M3 32-bit RISC core
Input Functions
Input specifications
Supports up to 4 universal analog inputs
Voltage input
0-5V, 1-5V, 0-20MV, 0-100MV
Current input
0-10mA, 4-20mA, 0-20mA
Resistance input
RES (0-400Ω)
Thermistor
PT100, CU50, G53, CU100, BA1, BA2
Thermocouple
s, b, k, t, r, e, n, j
Radiation Pyrometer
F1, F2
Tungsten Rhenium
WRE3-25, WRE5-26
Note
Other input signals (e.g. 0-10V) or index numbers (e.g. PT1000) must be specified when ordering
Output Functions
Distribution output
Supports 1 channel for transmitter centralized power distribution +24VDC, power distribution <60mA
Transformer output
Support up to 2 channels of 4-20mA standard current transducer output, 500Ω load capacity (maximum), convenient for display
instrument or DCS/PLC acquisition, realize the long distance transmission of signal
Relay alarm output
Support up to 4 channels relay alarm output, contact capacity 3A@250VAC / 3A@30VDC, can be configured upper limit, upper limit,
lower limit, lower limit alarm.
Communication Function
Communication interface
RS232C and RS485 communication interface for user to choose, support MODBUS RTU protocol, baud rate (1200, 4800, 9600, 19200,
38400, 57600)
Printing interface
RS232C direct connection to micro printer, baud rate 1200
Power supply
220VAC, 50HZ AC power supply, support 24VDC (18-36VDC), support 12VDC (9-18VDC), Note: DC power supply should be specified when
ordering.
Accuracy
Thermocouple cold end compensation error ±2ºC
Clock error: 2 seconds / day
Working Environment
Ambient temperature
0-50°C (avoid e.g. direct sunlight)
Ambient humidity
0-85%R.H. (no condensation)
Altitude <2000m (prohibited to work in flammable and corrosive environment)

Detailed Photos

Analog Inputs Paperless Recorder Control UnitAnalog Inputs Paperless Recorder Control UnitAnalog Inputs Paperless Recorder Control Unit


Product Showing

Analog Inputs Paperless Recorder Control UnitAnalog Inputs Paperless Recorder Control UnitAnalog Inputs Paperless Recorder Control UnitAnalog Inputs Paperless Recorder Control Unit


Certifications


Analog Inputs Paperless Recorder Control Unit

Analog Inputs Paperless Recorder Control UnitAnalog Inputs Paperless Recorder Control UnitAnalog Inputs Paperless Recorder Control UnitAnalog Inputs Paperless Recorder Control Unit
FAQ

1. Q: Can I buy any of your product accessories?

A: Yes, most accessories are available for purchase. However, certain patented designs or intellectual property may be restricted. Please contact our sales team for more information.
sold. For more details, please reach out to our sales team.

2. Q: Can I be your exclusive distributor?

A: Yes, we do offer exclusive distributor opportunities. However, this depends on your annual purchase volume and our mutual trust. We seek long-term, reliable business partners.
a long-term, trust-based partnership with us.

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

From payment to delivery, we protect your trading.
Analog Inputs Paperless Recorder Control Unit pictures & photos
Analog Inputs Paperless Recorder Control Unit
US $108-240 / Piece
Min. Order: 1 Piece
Diamond Member Since 2023

Suppliers with verified business licenses

Secured Trading Service
Rating: 5.0/5
Trading Company
Number of Employees
16
Year of Establishment
2020-06-16