• Air Velocity Measuring Doppler Sensor
  • Air Velocity Measuring Doppler Sensor
  • Air Velocity Measuring Doppler Sensor
  • Air Velocity Measuring Doppler Sensor
  • Air Velocity Measuring Doppler Sensor
  • Air Velocity Measuring Doppler Sensor

Air Velocity Measuring Doppler Sensor

After-sales Service: 1 Year
Warranty: 1 Year
Accuracy: ±0.6-1%
Main Application: Water, Wastewater
Size: DN100-500
Sensor: Plug-in
Samples:
US$ 1905/Piece 1 Piece(Min.Order)
| Request Sample
Customization:
Diamond Member Since 2023

Suppliers with verified business licenses

Rating: 5.0/5
Trading Company
  • Overview
  • Product Description
  • Product Parameters
  • Detailed Photos
  • Installation Instructions
  • Certifications
  • FAQ
Overview

Basic Info.

Model NO.
RC-DP-101-C4
Application
Industrial Production
Type
Ultrasonic Flow Meter
Measuring Media
Liquid
Measuring Principle
Acoustics
Measurement Object
Open Channel
Certification
CE, ISO
Flow Rate Range
0~10m/S
Flow Rate Resolution
0.001m/S
Velocity Accuracy
0.001m/S (When Velocity <= 5m/S)
Ultrasonic Level Range
6.5m
Ultrasonic Level Accuracy
0.001m
Ultrasonic Level Resolution
0.0005m
Hydrostatic Level Range
0~10m
Hydrostatic Level Accuracy
±0.1%Fs
Hydrostatic Level Resolution
0.001m
Temperature Range
-20~60ºC
Install
Special Bracket
Material
Metal, POM, Rubber
Protection Class
IP68
Powered by
DC12V/24V
Power Consumption
<90mA During Measurement; <25mA During Sleep
Transport Package
Cartons
Specification
50*25*22CM 3KG
Trademark
Aice Tech
Origin
China
HS Code
9026100000
Production Capacity
5000000/Pieces

Product Description

Welcome to Jiangsu Aice Instrument Technology Co., Ltd., where cutting-edge technology meets unparalleled precision. Discover our innovative solutions and experience excellence in every detail.

Product Description

The Acoustic Doppler Point Flowmeter is an advanced flow detection instrument designed specifically for rivers, open channels, and pipelines. Leveraging state-of-the-art ultrasonic detection technology, this device boasts exceptional measurement accuracy and robust stability. It remains unaffected by environmental variables, eliminates the need for rotating parts, and ensures minimal maintenance. High working reliability makes it the premier choice for both online and portable measurement applications.

Utilizing the Doppler effect, this sensor accurately correlates the frequency difference between transmission and reception with flow velocity. Additionally, it calculates the time difference between ultrasonic transmission and reception to determine liquid levels. Designed to handle special working conditions, it also measures static pressure levels and ambient temperature to correct the actual speed of ultrasonic propagation, delivering precise and reliable measurements every time.

Air Velocity Measuring Doppler Sensor

Product Parameters

  • Flow rate range
    0~10m/s
    Flow rate resolution
    0.001m/s
    Velocity Accuracy
    0.001m/s (when velocity <= 5m/s); 0.02m/s or 0.3% of actual peak velocity (whichever is greater) (when velocity > 5m/s)
    Ultrasonic Level Range
    6.5m
    Ultrasonic Level Accuracy
    0.001m
    Ultrasonic level resolution
    0.0005m
    Hydrostatic level range
    0~10m
    Hydrostatic level accuracy
    ±0.1%FS
    Hydrostatic level resolution
    0.001m
    Temperature range
    -20~60ºC
    Install
    Special bracket
    material
    Metal, POM, Rubber
    Protection class
    IP68
    Powered by
    DC12V/24V
    Power consumption
    <90mA during measurement; <25mA during sleep
    Communication Interface
    RS485, Modbus
    Working temperature
    -20~60ºC
    Work pressure
    Max 6Bar
Detailed Photos

Air Velocity Measuring Doppler Sensor

Air Velocity Measuring Doppler Sensor
Installation Instructions

Leveraging the Doppler effect, our sensor masterfully correlates the frequency differential between transmission and reception with flow velocity. It also establishes a precise relationship between the time difference in ultrasonic transmission/reception and liquid level. Designed for special working conditions, it measures static pressure levels and ambient temperatures to adjust the actual speed of ultrasonic propagation.
1.1.2 CCharacteristics
Crafted from industrial-grade stainless steel and robust industrial plastic, our sensor boasts waterproof, anti-corrosion properties, ensuring it is both strong and durable.
Engineered with no wearing parts, this sensor requires minimal maintenance, offering a cost-effective solution for long-term use.
High resolution and exceptional measurement accuracy set this sensor apart.
Engineered for longevity, the sensor is built to last over 5 years.
Unaffected by chemical reagents, liquid viscosity, and other disrupting factors, ensuring reliable performance.
User-friendly 18-key keypad operation, featuring both Chinese and English language menus.
Provides isolated 4~20mA current output for seamless integration.
Equipped with an isolated RS485 (Modbus RTU) communication interface for enhanced connectivity.
Includes a relay output for upper and lower limit alarm functions, offering comprehensive monitoring capabilities.

2.1 Installation Instructions
For the installer’s safety and to ensure optimal sensor operation, follow these steps in order:
:
1) Securely mount the meter box and sensor bracket.
2) Insert the meter head into the case, ensuring it’s firmly secured.
3) Install the sensor meticulously.
4) Proceed with the electrical connection carefully.

2.2 Mainframe Installation
Choose between embedded and wall-mounted installation for the mainframe.
1) External dimensions: 176 x 150 x 86mm.

Air Velocity Measuring Doppler Sensor

Wall mounting dimensions: 167 x 105mm.
Designed with four quick wall mounting holes. Fix the screws according to the wall mounting points, then hang the product securely.
Note: During probe installation, ensure British line commissioning products are fixed. Protect the instrument from sun and water to extend its service life.
Air Velocity Measuring Doppler Sensor

2.3 Sensor Installation
Precautions:
1) Avoid shocking the sensor!
2) Do not loosen the locking wire connector on the sensor during installation to prevent damage.
3) Ensure water does not freeze around the sensor to avoid damage.
Sensor dimensions are as follows:
Air Velocity Measuring Doppler Sensor

1) Follow these guidelines when selecting a sensor mounting location:
2) Position the sensor where it will provide representative measurement results.
3) Install the sensor in an easily accessible spot for convenient regular cleaning.
4) Place the sensor in a well-mixed part of the process with no downtime, typically near the sampling point.
5) Install the sensor near a representative process sampling point, within 1.5m (5 feet) for optimal calibration and use. This facilitates accurate comparison of instrument readings with laboratory analysis results. Incorrect sampling is a common source of erroneous readings.

2.4 Sensor Installation Method
The installation of the Doppler Sensor via a mounting bracket, ensuring its immersion within the channel or pipe, is ideal for general open channels, pipelines, and similar scenarios. This method guarantees optimal performance and accuracy in various environments.
For optimal performance, the sensor must be securely installed on the mounting bracket. Under no circumstances should the sensor be suspended in water by the sensor cable alone. Ensure the sensor is submerged to a minimum depth of 30cm below the water surface, or to the typical sampling depth, while avoiding direct exposure to intense light.
1) Selection of Installation Site
Select a location with smooth and steady water flow to achieve precise measurements.
In areas where water flow is irregular or turbulent, the measured flow velocity tends to be erratic and unstable, leading to significant measurement errors.
2) Upstream and Downstream Channel Requirements
Under ideal conditions, select an installation site with an upstream straight channel length of 10 times the channel width, and a downstream straight channel length of 3 times the channel width to ensure accurate measurements.
Air Velocity Measuring Doppler Sensor

The longer the straight upstream channel, the better the results. Smooth water flow ensures that the velocity measurements are more accurate to the actual flow. This section should remain free from obstructions such as gates or weirs, ensuring a smooth flow pattern ahead of the sensor and minimizing turbulence.

Certifications


Air Velocity Measuring Doppler Sensor

Air Velocity Measuring Doppler SensorAir Velocity Measuring Doppler SensorAir Velocity Measuring Doppler SensorAir Velocity Measuring Doppler Sensor
FAQ

1. Q: Can I buy any of your product accessories?

A: Yes, you certainly can! The majority of our accessories are available for purchase. However, there are some exceptions due to patented designs or intellectual property restrictions.
For more information, please reach out to our sales team for personalized assistance.

2. Q: Can I become your exclusive distributor?

A: Absolutely! Though this opportunity is contingent upon your annual purchase volume and our long-term business relationship. We are looking for partners who can establish a lasting and trustworthy relationship with us.
Together, we can build a future based on mutual trust and shared success.

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now