After-sales Service: 1 Year
Warranty: 1 Year
Accuracy: ±0.6-1%
Main Application: Water, Wastewater
Size: DN100-500
Sensor: Plug-in
Samples:
US$ 1905/Piece 1 Piece(Min.Order)
| Request Sample
Customization:
Diamond Member Since 2023

Suppliers with verified business licenses

Rating: 5.0/5
Trading Company
  • Overview
  • Product Description
  • Product Parameters
  • Detailed Photos
  • Installation Instructions
  • Certifications
  • FAQ
Overview

Basic Info.

Model NO.
RC-DP-101-C4
Application
Industrial Production
Type
Ultrasonic Flow Meter
Measuring Media
Liquid
Measuring Principle
Acoustics
Measurement Object
Open Channel
Certification
CE, ISO
Flow Rate Range
0~10m/S
Flow Rate Resolution
0.001m/S
Velocity Accuracy
0.001m/S (When Velocity <= 5m/S)
Ultrasonic Level Range
6.5m
Ultrasonic Level Accuracy
0.001m
Ultrasonic Level Resolution
0.0005m
Hydrostatic Level Range
0~10m
Hydrostatic Level Accuracy
±0.1%Fs
Hydrostatic Level Resolution
0.001m
Temperature Range
-20~60ºC
Install
Special Bracket
Material
Metal, POM, Rubber
Protection Class
IP68
Powered by
DC12V/24V
Power Consumption
<90mA During Measurement; <25mA During Sleep
Transport Package
Cartons
Specification
50*25*22CM 3KG
Trademark
Aice Tech
Origin
China
HS Code
9026100000
Production Capacity
5000000/Pieces

Product Description

Welcome to Jiangsu Aice Instrument Technology Co., Ltd., a pioneering force in the realm of advanced instrumentation. Our commitment to excellence drives us to deliver high-precision solutions that empower industries worldwide. Join us on a journey where innovation meets reliability.

Product Description

The Acoustic Doppler Point Flowmeter is an advanced flow detection instrument designed specifically for rivers, open channels, and pipelines. Leveraging state-of-the-art ultrasonic detection technology, this flowmeter offers unparalleled measurement accuracy and exceptional stability. Its performance remains robust with minimal influence from environmental factors. Engineered with no rotating parts, it requires low maintenance and ensures high operational reliability. Whether for online monitoring or portable measurements, it stands as the premier choice in flow detection solutions.

Harnessing the Doppler effect, this sensor precisely correlates the frequency difference between transmission and reception with flow velocity. Additionally, it utilizes the time difference between ultrasonic transmission and reception to accurately gauge liquid levels. For challenging working conditions, it provides static pressure level measurements and corrects the actual speed of ultrasonic propagation through ambient temperature readings. This meticulous approach guarantees highly reliable and precise flow measurements.

Doppler Ultrasonic Flow Rate Velocity Sensor

Product Parameters

  • Flow rate range
    0~10m/s
    Flow rate resolution
    0.001m/s
    Velocity Accuracy
    0.001m/s (when velocity <= 5m/s); 0.02m/s or 0.3% of actual peak velocity (whichever is greater) (when velocity > 5m/s)
    Ultrasonic Level Range
    6.5m
    Ultrasonic Level Accuracy
    0.001m
    Ultrasonic level resolution
    0.0005m
    Hydrostatic level range
    0~10m
    Hydrostatic level accuracy
    ±0.1%FS
    Hydrostatic level resolution
    0.001m
    Temperature range
    -20~60ºC
    Install
    Special bracket
    material
    Metal, POM, Rubber
    Protection class
    IP68
    Powered by
    DC12V/24V
    Power consumption
    <90mA during measurement; <25mA during sleep
    Communication Interface
    RS485, Modbus
    Working temperature
    -20~60ºC
    Work pressure
    Max 6Bar
Detailed Photos

Doppler Ultrasonic Flow Rate Velocity Sensor

Doppler Ultrasonic Flow Rate Velocity Sensor
Installation Instructions

Leveraging the Doppler effect, this sensor accurately computes flow velocity by examining the frequency difference between transmission and reception. Additionally, it establishes a relationship with liquid levels based on the time difference in ultrasonic transmission and reception. Designed for special working conditions, it measures static pressure levels and ambient temperature to correct the actual speed of ultrasonic propagation.
1.1.2 CCharacteristics
Crafted from industrial stainless steel and industrial plastic materials, our sensor is waterproof, anti-corrosive, and built to be strong and durable.
Engineered with no wearing parts, our sensor promises less maintenance and a low cost of use.
Experience high resolution and exceptional measurement accuracy.
Our sensors have a remarkable service life exceeding 5 years.
Resistant to interference from chemical reagents, liquid viscosity, and other factors, ensuring reliable performance.
User-friendly with an 18-key keypad operation and dual Chinese and English menus.
Features a 4~20mA isolated current output for versatile applications.
Equipped with an isolated RS485 (Modbus RTU) communication interface for seamless integration.
Comes with upper and lower limit alarm function relay output for enhanced operational safety.

2.1 Installation Instructions
To guarantee installer safety and optimal sensor performance, please follow these steps in order:
:
1) Securely mount the meter box and sensor bracket.
2) Insert and secure the meter head into the meter case.
3) Proceed with mounting the sensor.
4) Complete the electrical connection.

2.2 Mainframe Installation
The mainframe supports two installation types: embedded and wall-mounted.
1) External dimensions of the mainframe: 176 x 150 x 86mm.

Doppler Ultrasonic Flow Rate Velocity Sensor

Wall mounting dimensions: 167 x 105mm
Quick and easy installation with four wall mounting holes. Simply fix the screws at the designated points and hang the mainframe securely.
Note: When commissioning products with British line, ensure the probe is securely fixed. Protect the instrument from direct sunlight and water to extend its service life.
Doppler Ultrasonic Flow Rate Velocity Sensor

2.3 Sensor Installation
Precautions:
1) Avoid any shock to the sensor!
2) Do not unscrew the locking wire connector on the sensor during installation; this may cause damage!
3) Ensure that water surrounding the sensor does not freeze to prevent damage!
Sensor dimensions are shown below:
Doppler Ultrasonic Flow Rate Velocity Sensor

1) Follow these criteria when selecting a sensor mounting location:
2) Mount the sensor at an appropriate location to ensure accurate and representative measurements.
3) Install the sensor in an accessible location for regular cleaning.
4) Place the sensor in a well-mixed area of the process without downtime, typically near the sampling point.
5) Position the sensor near a convenient process sampling point within 1.5m (5 feet) for accurate calibration and comparison with laboratory analysis. Proper sampling operations are crucial to avoid erroneous comparison results.

2.4 Sensor Installation Method
The optimal installation method involves immersing the Doppler Ultrasonic Flow Rate Velocity Sensor in the channel or pipeline through a mounting bracket. This technique is perfect for general open channels, pipelines, and similar contexts, ensuring reliable performance and accurate data collection.
Ensure the sensor is securely installed on a mounting bracket; never suspend the sensor in water by the sensor cable. For optimal results, immerse the sensor to a depth of at least 30 cm below the water surface, or to the typical depth for sampling. Additionally, avoid direct exposure to intense light to maintain sensor efficiency and longevity.
1) Selection of Installation Site
Select a location with steady, smooth water flow for precise measurement results.
In areas where water flow is turbulent and erratic, velocity readings can be inconsistent and unstable, resulting in significant measurement errors. Thus, it's essential to avoid such locations.
2) Specifications for Upstream and Downstream Channels
Ideally, the installation site should have an upstream channel width approximately 10 times the straight channel and a downstream width about 3 times the straight channel.
Doppler Ultrasonic Flow Rate Velocity Sensor

The longer the straight upstream channel, the smoother the water flow will be, leading to measurement results that more accurately reflect actual flow conditions. This channel section should be free from obstructions like gates or weirs to ensure a smooth, turbulence-free flow pattern in front of the sensor.

Certifications


Doppler Ultrasonic Flow Rate Velocity Sensor

Doppler Ultrasonic Flow Rate Velocity SensorDoppler Ultrasonic Flow Rate Velocity SensorDoppler Ultrasonic Flow Rate Velocity SensorDoppler Ultrasonic Flow Rate Velocity Sensor
FAQ

1. Q: Can I buy any of your product accessories?

A: Absolutely! Most of our accessories are available for purchase. However, please be aware that a few items, due to patented designs or intellectual property restrictions, may not be available.
For more detailed information, please feel free to reach out to our dedicated sales team.

2. Q: Can I be your exclusive distributor?

A: Certainly! However, this opportunity depends on your annual purchase volume and the potential for a long-term partnership. We are looking for business partners who can cultivate a long-term, trust-filled relationship.
We believe in forming lasting bonds of trust with our exclusive distributors.

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now