Absolute Pressure Modbus Transmitter Sensor

Measuring Medium: Gas
Model Measuring Core: Ceramic Chip
Measuring Temperature: -20~50ºC
Samples:
US$ 9/Piece 1 Piece(Min.Order)
| Order Sample
Customization:
Shipping Cost:

Estimated freight per unit.

about shipping cost and estimated delivery time.
Payment Method: visa mastercard discover JCB diners club american express T/T
  Initial Payment Full Payment
Currency: US$
Return&refunds: You can apply for a refund up to 30 days after receipt of the products.
From payment to delivery, we protect your trading.
Absolute Pressure Modbus Transmitter Sensor pictures & photos
Absolute Pressure Modbus Transmitter Sensor
US $23.8-31.7 / Piece
Min. Order: 1 Piece
Diamond Member Since 2023

Suppliers with verified business licenses

Secured Trading Service
Rating: 5.0/5
Trading Company
  • Overview
  • Product Description
  • Product Parameters
  • Installation Instructions
  • Product Showing
  • Certifications
  • FAQ
Overview

Basic Info.

Model NO.
SAC-131WX
Measurement Form
Gauge Pressure, Absolute Pressur
Measurement Range
-0.1MPa ~ 0MPa ~ 6MPa
Measurement Accuracy
0.5%F.S
Measurement Stability
±0.2%Fs/Year
Overload Pressure
150%Fs
Operating Temperature
-20~50ºC
Compensation Temperature
-20~50ºC
Working Humidity
95%Rh
Storage Temperature
-40~85ºC
Trademark
Aice Tech
Origin
China
HS Code
9026202000

Product Description

Welcome to Jiangsu Aice Instrument Technology Co., Ltd., your trusted partner in advanced instrumentation solutions.

Product Description

1. INTRODUCTION

This cutting-edge protocol adheres impeccably to the MODBUS communication standards, employing the centralized RTU mode with RS485 half-duplex for seamless and efficient data exchange.

Serial port configuration: No parity, 8 data bits, and 1 stop bit for optimized performance.
Example Configuration: 9600,N,8,1 - Interpreted as: 9600 bps, no parity, 8 data bits, and 1 stop bit.
Our transmitter supports an extensive range of serial baud rates including: 1200, 2400, 4800, 9600, 19200, 38400, 57600, and 115200.
CRC checksum polynomial: 0xA001 ensures data integrity.
The data communication process is meticulously handled in compliance with double-byte shaped data format. For floating point numbers, ensure to read the decimal point to accurately interpret the data magnitude.
Absolute Pressure Modbus Transmitter Sensor

Product Parameters

(1) Exemplary Command Format for Reading (Function Code 03)
A. Send the Read Command Format.
Address Function Code Data start(H) Data start(L) Data number(H) Data number(L) CRC16
(L)
CRC16(H)
0X01 0X03 0X00 0X00 0X00 0X01 0X84 0X0A

B. Return Data Format for Reading: Illustration
Address Function Code Data length Data(H) Data(L) CRC16
(L)
CRC16(H)
0X01 0X03 0X02 0X00 0X01 0X79 0X84


(2) Exemplary Command Format for Writing (Function Code 06)
A. Send the Write Command Format.
Address Function Code Data start(H) Data start(L) Data number(H) Data number(L) CRC16
(L)
CRC16(H)
0X01 0X06 0X00 0X00 0X00 0X02 0X08 0X0B

  1. Return Data Format for Writing: Illustration
Address Function Code Data start(H) Data start(L) Data(H) Data(L) CRC16
(L)
CRC16(H)
0X01 0X06 0X00 0X00 0X00 0X02 0X08 0X0B

  1. Handling Exception Responses
Address Function Code Exception code CRC16(L) CRC16(H)
0X01 0X80+Function Code 0X01(Illegal functions)    
0X02(Illegal data address)    
0X03(Illegal data)    

4. Supported Commands: Their Meanings and Data Interpretations
Function Code Data start address Data number Data bytes Data range Command Meaning
0x03 Function code to read data
0x03 0x0000 1 2 1-255 Read slave address
0x03 0x0001 1 2
  1. 1200
 
Baud rate reading

0x03 0x0003 1 2
  1. ####
  1. ###.#
  2. ##.##
  3. #.###
The decimal points represent respectively
0-3 decimal places
0x03 0x0002 1 2 0- Mpa
1- Kpa
2- Pa
3- Bar
4- Mbar
5- kg/cm2
6- psi
7- mh2o
8- mmh2o
 
Pressure units
0x03 0x0004 1 2 -32768~32767 Measured output Value
0x03 0x0005 1 2 -32768~32767 Transmitter range zero point
0x03 0x0006 1 2 -32768~32767 Transmitter range full point
0x03 0x000C 1 2 -32768~32767 Zero offset value, factory default is 0
0x06 Function code reading data
0x06 0x0000   2 1-255  
0x06 0x0001   2
  1. 1200
  1. 2400
  2. 4800
  3. 9600
  4. 19200
  5. 38400
  6. 57600
  7. 115200
Modify baud rate
0x06 0x000C   2 -32768~32767 Zero offset value
Pressure output value = calibration measurement value + zero offset value
           
0x06 0x000F   2 0-Save to user area
1-Save to factory area
 
0x06 0x0010   2 1-Return factory parameters  


Installation Instructions



When altering the baud rate, the transmitter effortlessly responds with the baud rate provided by the host for modification. Upon response, the transmitter's baud rate seamlessly transitions to the newly specified value.
Upon changing the address, the transmitter promptly acknowledges with the pre-update address. Following the acknowledgment, the transmitter's address is automatically updated to the new value.
When you execute the save and reply factory command, the transmitter returns the original value, signifying its successful acceptance of the host's command.
Note that restoring factory data may result in differences in parameters saved by the factory compared to user-saved settings. This includes address, baud rate, and calibration data—requiring a re-search for the transmitter after restoration.
Users are authorized to modify only three parameters: address, baud rate, and zero offset.
For calibration or changes in calibration data, please contact our company to obtain the necessary calibration software. User-initiated commands to alter calibration data will result in the transmitter outputting a command exception code. Always use our provided calibration software for such modifications.
Should the data to be read be a floating-point number, such as 6.000, the protocol mandates communication as an integer. Thus, the data reads as 6000. To convert it, utilize the decimal point for calculation: e.g., with a decimal point of 3, 6000/10^3 results in 6.000.
Product Showing

Absolute Pressure Modbus Transmitter SensorAbsolute Pressure Modbus Transmitter SensorAbsolute Pressure Modbus Transmitter Sensor


Certifications


Absolute Pressure Modbus Transmitter Sensor

Absolute Pressure Modbus Transmitter SensorAbsolute Pressure Modbus Transmitter SensorAbsolute Pressure Modbus Transmitter SensorAbsolute Pressure Modbus Transmitter Sensor
FAQ

1. Q: Can I purchase accessories for any of your products?

A: Absolutely! While most accessories are available for purchase, please note that certain items with patented designs or protected intellectual property may not be for sale.
For more detailed information, please contact our dedicated sales team.

2. Q: Is it possible to become an exclusive distributor for your products?

A: Yes, it is possible. However, this opportunity depends on your annual purchase volume and the potential for a long-term, mutually beneficial relationship. We seek partners who are committed to fostering a reliable and enduring business partnership.
Together, we aim to establish a trusting and long-lasting collaboration.

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

From payment to delivery, we protect your trading.
Absolute Pressure Modbus Transmitter Sensor pictures & photos