• Variable Transmission Multi-Channel Temperature Logger
  • Variable Transmission Multi-Channel Temperature Logger
  • Variable Transmission Multi-Channel Temperature Logger
  • Variable Transmission Multi-Channel Temperature Logger
  • Variable Transmission Multi-Channel Temperature Logger
  • Variable Transmission Multi-Channel Temperature Logger

Variable Transmission Multi-Channel Temperature Logger

Display: Screen 128*64 DOT Matrix White Screen (LCD)
Weight: 0-100Kg
Processor: High-Performance Arm Cortex-M3 32-Bit Risc Core
Samples:
US$ 240/Piece 1 Piece(Min.Order)
| Order Sample
Customization:
Shipping Cost:

Estimated freight per unit.

about shipping cost and estimated delivery time.
Payment Method: visa mastercard discover JCB diners club american express T/T
  Initial Payment Full Payment
Currency: US$
Return&refunds: You can apply for a refund up to 30 days after receipt of the products.
From payment to delivery, we protect your trading.
Variable Transmission Multi-Channel Temperature Logger pictures & photos
Variable Transmission Multi-Channel Temperature Logger
US $108-240 / Piece
Min. Order: 1 Piece
Diamond Member Since 2023

Suppliers with verified business licenses

Secured Trading Service
Rating: 5.0/5
Trading Company
  • Overview
  • Product Description
  • Product Parameters
  • Detailed Photos
  • Product Showing
  • Certifications
  • FAQ
Overview

Basic Info.

Model NO.
GL-R2100E
Input Function
Support up to 4-Wire Analog Inputs
Output Function
Power Distribution, Variable Transmission, Relay a
Communication Function
Interface Provide RS232c and RS485, Modbus RTU
Power Supply
220VAC, 50Hz AC; 24VDC (18-36VDC), 12VDC (9-18VDC)
Accuracy
Thermocouple Cold End Comp. Error &Plusmn
Operating Environment1
Temperature 0-50ºC (Avoid Direct Sunlight)
Operating Environment2
Humidity 0-85%R.H. (No Condensation)
Meter Weight
≤1kg
Trademark
Aice Tech
Origin
China
HS Code
9026202000

Product Description

Welcome to Jiangsu Aice Instrument Technology Co., Ltd.

Product Description

1. INTRODUCTION

This advanced instrument is designed for general industrial applications, ensuring optimal performance across various settings.
For specialized applications, please ensure dedicated protection for the device.
Do not operate it in explosive atmospheres; maintain proper ventilation at the installation site.
Ensure the installation site is well-ventilated.
Use the rated voltage of the power supply, ensure correct wiring, and proper grounding to ensure safety.
Do not touch the terminals on the back of the device to avoid electric shock.
For safety, ensure the device is uncharged during installation, maintenance, and removal.
During installation, maintenance, and removal, make sure the device is not charged to ensure safety.
To avoid measurement errors, shielding measures should be taken if the device is placed near mains power, high electric fields, high magnetic fields, or AC contactors.
Appropriate shielding measures are necessary when the device is close to mains power, high electric fields, high magnetic fields, or AC contactors.
Ensure proper shielding if the device is near mains power, high electric fields, high magnetic fields, or AC contactors.
To prevent measurement errors: If the sensor is a thermocouple, use the corresponding compensating wire; if it's a thermal resistance sensor, use three identical copper conductors with resistance less than 10Ω.
To avoid measurement errors: use corresponding compensating wires for thermocouples and identical copper conductors with less than 10Ω resistance for thermal resistance sensors.
For accurate measurements: use appropriate compensating wires for thermocouples and three identical copper conductors with resistance under 10Ω for thermal resistance sensors.
Product Parameters
Detailed Photos
Variable Transmission Multi-Channel Temperature Logger

Product Parameters

Display
Screen
128*64 dot matrix white screen liquid crystal display (LCD)
Accuracy
Real-time display: ±0.2% F.S. Trace accuracy: ±0.2% F.S.
(Thermocouple should remove the cold end error)
Processor
Adopts high-performance ARM CORTEX-M3 32-bit RISC core
Input Functions
Input specifications
Supports up to 4 universal analog inputs
Voltage input
0-5V, 1-5V, 0-20MV, 0-100MV
Current input
0-10mA, 4-20mA, 0-20mA
Resistance input
RES (0-400Ω)
Thermistor
PT100, CU50, G53, CU100, BA1, BA2
Thermocouple
s, b, k, t, r, e, n, j
Radiation Pyrometer
F1, F2
Tungsten Rhenium
WRE3-25, WRE5-26
Note
Other input signals (e.g. 0-10V) or index numbers (e.g. PT1000) must be specified when ordering
Output Functions
Distribution output
Supports 1 channel for transmitter centralized power distribution +24VDC, power distribution <60mA
Transformer output
Support up to 2 channels of 4-20mA standard current transducer output, 500Ω load capacity (maximum), convenient for display
instrument or DCS/PLC acquisition, realize the long distance transmission of signal
Relay alarm output
Support up to 4 channels relay alarm output, contact capacity 3A@250VAC / 3A@30VDC, can be configured upper limit, upper limit,
lower limit, lower limit alarm.
Communication Function
Communication interface
RS232C and RS485 communication interface for user to choose, support MODBUS RTU protocol, baud rate (1200, 4800, 9600, 19200,
38400, 57600)
Printing interface
RS232C direct connection to micro printer, baud rate 1200
Power supply
220VAC, 50HZ AC power supply, support 24VDC (18-36VDC), support 12VDC (9-18VDC), Note: DC power supply should be specified when
ordering.
Accuracy
Thermocouple cold end compensation error ±2ºC
Clock error: 2 seconds / day
Working Environment
Ambient temperature
0-50°C (avoid e.g. direct sunlight)
Ambient humidity
0-85%R.H. (no condensation)
Altitude <2000m (prohibited to work in flammable and corrosive environment)

Detailed Photos

Variable Transmission Multi-Channel Temperature LoggerVariable Transmission Multi-Channel Temperature LoggerVariable Transmission Multi-Channel Temperature Logger


Product Showing

Variable Transmission Multi-Channel Temperature LoggerVariable Transmission Multi-Channel Temperature LoggerVariable Transmission Multi-Channel Temperature LoggerVariable Transmission Multi-Channel Temperature Logger


Certifications


Variable Transmission Multi-Channel Temperature Logger

Variable Transmission Multi-Channel Temperature LoggerVariable Transmission Multi-Channel Temperature LoggerVariable Transmission Multi-Channel Temperature LoggerVariable Transmission Multi-Channel Temperature Logger
FAQ

2. Q: Can I be your exclusive distributor?

A: Yes, you can. However, this depends on your annual purchase volume and our long-term relationship. We seek business partners who can build a long-term relationship of mutual trust.
To explore this opportunity further, please connect with our sales team for more details.

A: Yes, you can. However, this depends on your annual purchase volume and long-term business relationship. We need partners who can establish a long-term relationship based on trust.

For more information, please reach out to our sales team.
We look forward to fostering a long-term, trust-based business relationship.

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

From payment to delivery, we protect your trading.
Variable Transmission Multi-Channel Temperature Logger pictures & photos
Variable Transmission Multi-Channel Temperature Logger
US $108-240 / Piece
Min. Order: 1 Piece
Diamond Member Since 2023

Suppliers with verified business licenses

Secured Trading Service
Rating: 5.0/5
Trading Company
Number of Employees
16
Year of Establishment
2020-06-16