Advanced Fuel Flow Integration and Data Recording Unit

Product Details
Customization: Available
Display: Screen 128*64 DOT Matrix White Screen (LCD)
Weight: 0-100Kg
Still deciding? Get samples of US$ 240/Piece
Order Sample
Shipping & Policy
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment Methods:
visa mastercard discover JCB diners club american express T/T
PIX SPEI OXXO PSE OZOW
  Support payments in USD
Secure payments: Every payment you make on Made-in-China.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.

360° Virtual Tour

Secured Trading Service
Diamond Member Since 2023

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Number of Employees
16
Year of Establishment
2020-06-16
  • Advanced Fuel Flow Integration and Data Recording Unit
  • Advanced Fuel Flow Integration and Data Recording Unit
  • Advanced Fuel Flow Integration and Data Recording Unit
  • Advanced Fuel Flow Integration and Data Recording Unit
  • Advanced Fuel Flow Integration and Data Recording Unit
  • Advanced Fuel Flow Integration and Data Recording Unit
Find Similar Products
  • Overview
  • Product Description
  • Product Parameters
  • Detailed Photos
  • Product Showing
  • Certifications
  • FAQ
Overview

Basic Info.

Model NO.
GL-F2000X
Accuracy
Real-Time Display: ±0.2% F.S.
Processing Unit
High-Performance Arm Cortex-M332-
Processor
High Performance Arm Cortex-M3 32 Bit R
Flow Channel
Analogue Signal:4-20mA,0-10mA and Ot
Frequency Signal
Pi
Temperature Channel
4-20mA,0-10mA,PT100 and Other
Pressure Channel
4-20mA,0-10mA and Other Signals
Distribution Output
Both 12VDC and 24VDC Distribu
Transmitter Output
Support 1 Flow Channel 4-20mA
Thermocouple Cold End Compensation Error
2c
Clock Error
±2 Seconds/Day
Trademark
Aice Tech
Origin
China
HS Code
9026202000

Product Description

Welcome to Jiangsu Aice Instrument Technology Co., Ltd. Your ultimate destination for cutting-edge instrumentation solutions.

Product Description

1. INTRODUCTION

Our Fuel Flow Integrator Processing Unit Recorder serves as a comprehensive flow accumulation controller. It collects, displays, controls, transmits, communicates, prints, and processes signals like temperature, pressure, and flow from the field. This sophisticated digital acquisition and control system boasts both liquid crystal and digital displays, offering various external dimensions to fit a myriad of applications. Whether measuring and controlling liquids, gases, superheated steam, or saturated steam flow, our unit excels in accuracy and versatility. The system supports quantitative and batch control of medium flows with start, stop, and clear functions. Compatible with various flow sensors and transmitters, it adapts seamlessly to diverse measurement and control scenarios.

Advanced Fuel Flow Integration and Data Recording Unit

Product Parameters

Pseudolaric acid 3.2-inch LCD Flow Calculator
Product Model GL-F2000X
Screen  128 * 64 dot matrix monochrome screen LCD display
Accuracy  Real-time display ±0.2% F.S.
Processing unit  High-performance ARM Cortex-M332-bit RISC Core
Flow channel  Analogue signal
Frequency signal  PI(frequency range
Temperature channel 4-20mA,0-10mA,Pt100 and other signals
Pressure channel 4-20mA,0-10mA and other signals
Distribution Output  Both 12VDC and 24VDC distribution,12VDC standard distribution <60mA,24VDCStandard distribution<30mA each way
Transmitter output  support 1 flow channel 4-20mA standard current transmitter output, load capacity ≤ 500Ω. Convenient for the acquisition of display instruments or DCS/PLC, and realises long-distance signal transmission.
Relay alarm output  support up to 2 relay alarm outputs, contact capacity A@250VAC/1A@30VDC (maximum contact capacity can be customised),upper limit, upper limit and lower limit can be configured,lower limit alarm
Communication interface  RS232C or RS485, supports Modbus RTUprotocol, baud rate -1200240048009600
Power supply  default 220VAC/50HZ AC power supply, support 24VDC or 12VDC DC power supply. Power supply (DC power supply should be specified when ordering)
Power failure protection  built-in memory to protect the parameters, permanent storage after power failure
Clock protection  integrated hardware clock for accurate operation even after power loss
Thermocouple cold end compensation error  ±2C
Clock error  ±2 seconds/day
Ambient temperature  0~50ºC (avoid direct sunlight)
Ambient humidity  0 to 85% R.H (non-condensing)
Net weight ≤1.5Kg
Ambient temperature  0~50ºC (avoid direct sunlight)
Ambient humidity 0 to 85% R.H (non-condensing)
Net weight ≤1.5Kg

Detailed Photos



Advanced Fuel Flow Integration and Data Recording UnitAdvanced Fuel Flow Integration and Data Recording Unit
Product Showing

Advanced Fuel Flow Integration and Data Recording UnitAdvanced Fuel Flow Integration and Data Recording UnitAdvanced Fuel Flow Integration and Data Recording UnitAdvanced Fuel Flow Integration and Data Recording UnitAdvanced Fuel Flow Integration and Data Recording Unit


Certifications


Advanced Fuel Flow Integration and Data Recording Unit

Advanced Fuel Flow Integration and Data Recording UnitAdvanced Fuel Flow Integration and Data Recording UnitAdvanced Fuel Flow Integration and Data Recording UnitAdvanced Fuel Flow Integration and Data Recording Unit
FAQ

1. Q: Can I buy any of your product accessories?

A: Yes, you can. Most accessories are available for purchase. However, certain patented designs or items protected by intellectual property laws may not be. For more details, please contact our sales team.
sold. More details please reach out with our sales team.

2. Q: Can I be your exclusive distributor?

A: Yes, you can. However, this depends on your annual purchase volume and the potential for a long-term partnership. We seek business partners who can establish a reliable, trust-based relationship with us.
a long-term relationship of trust with each other.

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now