Measuring Medium: Gas
Model Measuring Core: Ceramic Chip
Measuring Temperature: -20~50ºC
Samples:
US$ 9/Piece 1 Piece(Min.Order)
| Order Sample
Customization:
Shipping Cost:

Estimated freight per unit.

about shipping cost and estimated delivery time.
Payment Method: visa mastercard discover JCB diners club american express T/T
  Initial Payment Full Payment
Currency: US$
Return&refunds: You can apply for a refund up to 30 days after receipt of the products.
From payment to delivery, we protect your trading.
Modbus Protocol Ceramic Pressure Transmitter pictures & photos
Modbus Protocol Ceramic Pressure Transmitter
US $23.8-31.7 / Piece
Min. Order: 1 Piece
Diamond Member Since 2023

Suppliers with verified business licenses

Secured Trading Service
Rating: 5.0/5
Trading Company
  • Overview
  • Product Description
  • Product Parameters
  • Installation Instructions
  • Product Showing
  • Certifications
  • FAQ
Overview

Basic Info.

Model NO.
SAC-131WX
Measurement Form
Gauge Pressure, Absolute Pressur
Measurement Range
-0.1MPa ~ 0MPa ~ 6MPa
Measurement Accuracy
0.5%F.S
Measurement Stability
±0.2%Fs/Year
Overload Pressure
150%Fs
Operating Temperature
-20~50ºC
Compensation Temperature
-20~50ºC
Working Humidity
95%Rh
Storage Temperature
-40~85ºC
Trademark
Aice Tech
Origin
China
HS Code
9026202000

Product Description

Welcome to Jiangsu Aice Instrument Technology Co., Ltd., where cutting-edge technology meets unparalleled precision. Our dedication to innovation ensures that our products, such as the Modbus Protocol Ceramic Pressure Transmitter, set the benchmark in the industry.

Product Description

1. INTRODUCTION

Our Modbus Protocol Ceramic Pressure Transmitter adheres to the distinguished MODBUS communication standards. It operates efficiently under the sub-centralized RTU mode, utilizing RS485 half-duplex working mode to ensure seamless communication and optimal performance.

Serial port configuration is meticulously set to: no parity, 8 data bits, 1 stop bit, ensuring reliable and stable data transmission.
Example Configuration: 9600,N,8,1 translates to 9600bps baud rate, no parity, 8 data bits, and 1 stop bit, providing a standard and dependable setup.
This versatile transmitter supports an array of serial baud rates, including: 1200, 2400, 4800, 9600, 19200, 38400, 57600, and up to 115200, accommodating various communication needs.
For error-checking, the transmitter employs a CRC checksum polynomial of 0xA001, ensuring data integrity and accuracy.
The data communication process handles all data in double-byte format. For data identified as floating-point numbers, the decimal point must be read to accurately determine the value and magnitude.
Modbus Protocol Ceramic Pressure Transmitter

Product Parameters

(1) Exemplary Read Command Format (03 Function Code)
A. Transmit the Read Command Format.
Address Function Code Data start(H) Data start(L) Data number(H) Data number(L) CRC16
(L)
CRC16(H)
0X01 0X03 0X00 0X00 0X00 0X01 0X84 0X0A

B. Receive Data in the Read Format: Example
Address Function Code Data length Data(H) Data(L) CRC16
(L)
CRC16(H)
0X01 0X03 0X02 0X00 0X01 0X79 0X84


(2) Exemplary Write Command Format (06 Function Code)
A. Transmit the Write Command Format.
Address Function Code Data start(H) Data start(L) Data number(H) Data number(L) CRC16
(L)
CRC16(H)
0X01 0X06 0X00 0X00 0X00 0X02 0X08 0X0B

  1. Receive Data in the Write Format: Example
Address Function Code Data start(H) Data start(L) Data(H) Data(L) CRC16
(L)
CRC16(H)
0X01 0X06 0X00 0X00 0X00 0X02 0X08 0X0B

  1. Handling Exception Responses and Returns
Address Function Code Exception code CRC16(L) CRC16(H)
0X01 0X80+Function Code 0X01(Illegal functions)    
0X02(Illegal data address)    
0X03(Illegal data)    

4. Overview of Supported Commands and Their Significance
Function Code Data start address Data number Data bytes Data range Command Meaning
0x03 Function code to read data
0x03 0x0000 1 2 1-255 Read slave address
0x03 0x0001 1 2
  1. 1200
 
Baud rate reading

0x03 0x0003 1 2
  1. ####
  1. ###.#
  2. ##.##
  3. #.###
The decimal points represent respectively
0-3 decimal places
0x03 0x0002 1 2 0- Mpa
1- Kpa
2- Pa
3- Bar
4- Mbar
5- kg/cm2
6- psi
7- mh2o
8- mmh2o
 
Pressure units
0x03 0x0004 1 2 -32768~32767 Measured output Value
0x03 0x0005 1 2 -32768~32767 Transmitter range zero point
0x03 0x0006 1 2 -32768~32767 Transmitter range full point
0x03 0x000C 1 2 -32768~32767 Zero offset value, factory default is 0
0x06 Function code reading data
0x06 0x0000   2 1-255  
0x06 0x0001   2
  1. 1200
  1. 2400
  2. 4800
  3. 9600
  4. 19200
  5. 38400
  6. 57600
  7. 115200
Modify baud rate
0x06 0x000C   2 -32768~32767 Zero offset value
Pressure output value = calibration measurement value + zero offset value
           
0x06 0x000F   2 0-Save to user area
1-Save to factory area
 
0x06 0x0010   2 1-Return factory parameters  


Installation Instructions



To modify the baud rate, the transmitter will acknowledge by sending back the baud rate provided by the host. Once acknowledged, the transmitter's baud rate will seamlessly transition to the new specified value.
When changing the address, the transmitter will first respond with the current address. Following this acknowledgement, the transmitter will automatically update to the new address value.
Issuing the save and reply factory command will return the original data value, confirming that the transmitter has successfully accepted the host's command.
Please note, when restoring factory settings, the pre-saved factory parameters may differ from user-specific settings. Therefore, the address, baud rate, and calibration data may change. Ensure to re-scan the transmitter after restoring factory defaults.
Users are permitted to modify only three specific data points: address, baud rate, and zero offset.
For calibration or adjusting calibration data, please contact our company to obtain the transmitter's calibration software. Unauthorized command modifications by the user will result in a command exception code from the transmitter. Only use our provided calibration software for such operations.
When reading data identified as a floating point number, such as 6.000, note that the protocol communicates this data as integer values. For example, 6000 is read instead of 6.000, and to convert, divide by 10 raised to the decimal places, e.g., 6000/10^3 yields 6.000.
Product Showing

Modbus Protocol Ceramic Pressure TransmitterModbus Protocol Ceramic Pressure TransmitterModbus Protocol Ceramic Pressure Transmitter


Certifications


Modbus Protocol Ceramic Pressure Transmitter

Modbus Protocol Ceramic Pressure TransmitterModbus Protocol Ceramic Pressure TransmitterModbus Protocol Ceramic Pressure TransmitterModbus Protocol Ceramic Pressure Transmitter
FAQ

1. Q: Are your product accessories available for purchase?

A: Absolutely! Most of our accessories are available for purchase. However, please note that certain items with patented designs or exclusive intellectual property rights may not be available.
For further details and specific inquiries, please reach out to our dedicated sales team.

2. Q: Is it possible to become an exclusive distributor for your products?

A: Certainly! However, this privilege is primarily based on your annual purchase volume and our long-term business relationship. We seek committed business partners who can establish and maintain mutual trust over the long term.

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

From payment to delivery, we protect your trading.
Modbus Protocol Ceramic Pressure Transmitter pictures & photos
Modbus Protocol Ceramic Pressure Transmitter
US $23.8-31.7 / Piece
Min. Order: 1 Piece
Diamond Member Since 2023

Suppliers with verified business licenses

Secured Trading Service
Rating: 5.0/5
Trading Company
Number of Employees
16
Year of Establishment
2020-06-16