Durable Aice Tech LCD Pressure Transmitter with High Accuracy

Product Details
Customization: Available
Type: Differential Pressure Transmitter
Structure Type: Capacitive Pressure Transmitter

360° Virtual Tour

Diamond Member Since 2023

Suppliers with verified business licenses

Audited Supplier Audited Supplier

Audited by an independent third-party inspection agency

Number of Employees
16
Year of Establishment
2020-06-16
  • Durable Aice Tech LCD Pressure Transmitter with High Accuracy
  • Durable Aice Tech LCD Pressure Transmitter with High Accuracy
  • Durable Aice Tech LCD Pressure Transmitter with High Accuracy
  • Durable Aice Tech LCD Pressure Transmitter with High Accuracy
  • Durable Aice Tech LCD Pressure Transmitter with High Accuracy
  • Durable Aice Tech LCD Pressure Transmitter with High Accuracy
Find Similar Products

Basic Info.

Model NO.
SAC-YC-131
Accuracy Grade
0.5G
Pressure range
Customizable
IP Rating
Customizable
Certification
CE
Customized
Customized
Specification
26*21*16cm 1kg
Trademark
Aice Tech
Origin
China
HS Code
9025191010
Production Capacity
5000000/Pieces

Product Description

Durable Aice Tech LCD Pressure Transmitter with High AccuracyDurable Aice Tech LCD Pressure Transmitter with High AccuracyDurable Aice Tech LCD Pressure Transmitter with High AccuracyDurable Aice Tech LCD Pressure Transmitter with High AccuracyDurable Aice Tech LCD Pressure Transmitter with High Accuracy
a) To ensure utmost safety, ensure the installation of the Aice Tech Anti-Corrosion Digital Pressure Transmitter is conducted without any pressurization or power supply.
b) It is imperative that the transmitter is installed exclusively by a professional technician who has thoroughly read and comprehended the operational manual.
manual.
c) The transmitter is equipped with a diffused silicon oil-filled core, posing explosion risks if mishandled. For your safety, measuring oxygen is strictly forbidden.
To ensure safety, measuring oxygen is strictly prohibited.
d) This product is not designed for explosion-proof environments. Usage in such areas can result in severe personal injury and considerable material damage.
and significant material damage.
e) Refrain from measuring media that are incompatible with the transmitter’s contact material to avoid damage.
f) Upon receiving the product, inspect the packaging for integrity and confirm that the model and specifications align with your purchase.
specifications match the product you have purchased.
g) Do not undertake any modifications or alterations to the device.
Jiangsu Aice Instrument Technology Co., Ltd.h) Handle the transmitter with care. Avoid discarding it carelessly and do not use excessive force during installation.
i) For safe and reliable operation, it is advisable to install a three-valve set between the measurement point and the transmitter. This ensures the measured medium is introduced gradually and uniformly to both pressure cavities of the differential pressure transmitter.
between the measured point and the transmitter to ensure that the measured medium is slowly and evenly added to
the positive and negative pressure cavity of the differential pressure transmitter.
j) During installation, it is recommended that both ends of the pressure interface remain horizontal to minimize impact on the transmitter. If there is a mismatch between interface sizes, custom adapters may be used.
installation position has minimal impact on the transmitter. If the interface size and the field interface size does not
match, you can make your own adapters to connect.
k) Opt for installation in environments where temperature gradients are minimal.
l) In harsh conditions where lightning strikes or overvoltage may occur, it is advisable to install protective measures between the power supply and the transmitter.
dangerous damage, we recommend that users in the distribution box or between the power supply and the
transmitter to protect against lightning strikes and overvoltage.
m) When measuring steam or other high-temperature media, ensure the medium temperature does not exceed the transmitter’s operating limits. If necessary, install a cooling device.
exceed the working temperature limit of the transmitter. If necessary, a cooling device needs to be installed.
n) Install a pressure shut-off valve between the transmitter and the medium to facilitate maintenance and prevent blockage of the pressure port, thus ensuring measurement accuracy.
facilitate maintenance and prevent the pressure port from blocking and affecting the measurement accuracy.
o) As this product is a low-power device, ensure that the wiring is laid separately from high-power cables, adhering to national wiring standards (GB/T50312-2016).
the relevant national wiring standards (GB/T50312-2016) should be observed for wiring.
p) Confirm that the power supply voltage complies with the transmitter’s requirements and that the maximum static pressure is within the transmitter’s tolerance range.
maximum static pressure is within the tolerable range of this transmitter.
q) During pressure measurement, gradually pressurize and depressurize the transmitter to prevent sudden changes to high or low pressure.
pressurization to high pressure or decreasing to low pressure.
r) Ensure the transmitter is disconnected from the pressure source and power supply before disassembling to prevent any accidents caused by media ejection.
the transmitter to avoid accidents caused by media ejection.
s) The sensor is a precision device. Avoid disassembling it by yourself and refrain from touching the diaphragm to prevent damage.
the diaphragm to avoid damage to the product.
Jiangsu Aice Instrument Technology Co., Ltd.

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier