• Relay Output Data Recorder Control
  • Relay Output Data Recorder Control
  • Relay Output Data Recorder Control
  • Relay Output Data Recorder Control
  • Relay Output Data Recorder Control
  • Relay Output Data Recorder Control

Relay Output Data Recorder Control

Display: Screen 128*64 DOT Matrix White Screen (LCD)
Weight: 0-100Kg
Processor: High-Performance Arm Cortex-M3 32-Bit Risc Core
Samples:
US$ 240/Piece 1 Piece(Min.Order)
| Order Sample
Customization:
Shipping Cost:

Estimated freight per unit.

about shipping cost and estimated delivery time.
Payment Method: visa mastercard discover JCB diners club american express T/T
  Initial Payment Full Payment
Currency: US$
Return&refunds: You can apply for a refund up to 30 days after receipt of the products.
From payment to delivery, we protect your trading.
Relay Output Data Recorder Control pictures & photos
Relay Output Data Recorder Control
US $108-240 / Piece
Min. Order: 1 Piece
Diamond Member Since 2023

Suppliers with verified business licenses

Secured Trading Service
Rating: 5.0/5
Trading Company
  • Overview
  • Product Description
  • Product Parameters
  • Detailed Photos
  • Product Showing
  • Certifications
  • FAQ
Overview

Basic Info.

Model NO.
GL-R2100E
Input Function
Support up to 4-Wire Analog Inputs
Output Function
Power Distribution, Variable Transmission, Relay a
Communication Function
Interface Provide RS232c and RS485, Modbus RTU
Power Supply
220VAC, 50Hz AC; 24VDC (18-36VDC), 12VDC (9-18VDC)
Accuracy
Thermocouple Cold End Comp. Error &Plusmn
Operating Environment1
Temperature 0-50ºC (Avoid Direct Sunlight)
Operating Environment2
Humidity 0-85%R.H. (No Condensation)
Meter Weight
≤1kg
Trademark
Aice Tech
Origin
China
HS Code
9026202000

Product Description

Welcome to Jiangsu Aice Instrument Technology Co., Ltd., where innovation meets precision in industrial instrumentation!

Product Description

1. INTRODUCTION

This versatile instrument is designed for a wide range of general industrial applications, ensuring robust performance and reliability.
For specialized applications, please ensure the device is protected separately to maintain optimal functionality.
Avoid operating the device in explosive atmospheres and ensure proper ventilation at the installation site for safety.
Adequate ventilation is crucial at the installation site to ensure the device operates efficiently.
Use the rated voltage for the power supply, ensure correct wiring, proper grounding, and avoid touching the terminals at the back to prevent electric shock.
Proper grounding is essential, and avoid contact with the terminals on the back of the device to prevent electric shock.
For safety, ensure the device is not live during installation, maintenance, or removal.
During installation, maintenance, and removal, ensure the device is de-energized to guarantee safety.
Shielding measures are necessary when the device is installed near mains power, high electric fields, high magnetic fields, or AC contactors.
Implement shielding measures if the device is near mains power, high electric fields, magnetic fields, or AC contactors.
In highly electric or magnetic environments, shielding steps are essential to maintain device accuracy.
Shielding is crucial near mains power, high electric fields, magnetic fields, and AC contactors to prevent interference.
To avoid measurement errors with thermocouples, use corresponding compensating wires. For thermal resistance sensors, use three same copper conductors with resistance less than 10Ω.
Use corresponding compensating wires for thermocouple sensors to prevent measurement errors.
Thermal resistance sensors require three same copper conductors with a resistance of less than 10Ω for accurate readings.
Ensure measurement accuracy by using proper compensating wires for thermocouples and suitable copper conductors for thermal resistance sensors.
Relay Output Data Recorder Control

Product Parameters

Display
Screen
128*64 dot matrix white screen liquid crystal display (LCD)
Accuracy
Real-time display: ±0.2% F.S. Trace accuracy: ±0.2% F.S.
(Thermocouple should remove the cold end error)
Processor
Adopts high-performance ARM CORTEX-M3 32-bit RISC core
Input Functions
Input specifications
Supports up to 4 universal analog inputs
Voltage input
0-5V, 1-5V, 0-20MV, 0-100MV
Current input
0-10mA, 4-20mA, 0-20mA
Resistance input
RES (0-400Ω)
Thermistor
PT100, CU50, G53, CU100, BA1, BA2
Thermocouple
s, b, k, t, r, e, n, j
Radiation Pyrometer
F1, F2
Tungsten Rhenium
WRE3-25, WRE5-26
Note
Other input signals (e.g. 0-10V) or index numbers (e.g. PT1000) must be specified when ordering
Output Functions
Distribution output
Supports 1 channel for transmitter centralized power distribution +24VDC, power distribution <60mA
Transformer output
Support up to 2 channels of 4-20mA standard current transducer output, 500Ω load capacity (maximum), convenient for display
instrument or DCS/PLC acquisition, realize the long distance transmission of signal
Relay alarm output
Support up to 4 channels relay alarm output, contact capacity 3A@250VAC / 3A@30VDC, can be configured upper limit, upper limit,
lower limit, lower limit alarm.
Communication Function
Communication interface
RS232C and RS485 communication interface for user to choose, support MODBUS RTU protocol, baud rate (1200, 4800, 9600, 19200,
38400, 57600)
Printing interface
RS232C direct connection to micro printer, baud rate 1200
Power supply
220VAC, 50HZ AC power supply, support 24VDC (18-36VDC), support 12VDC (9-18VDC), Note: DC power supply should be specified when
ordering.
Accuracy
Thermocouple cold end compensation error ±2ºC
Clock error: 2 seconds / day
Working Environment
Ambient temperature
0-50°C (avoid e.g. direct sunlight)
Ambient humidity
0-85%R.H. (no condensation)
Altitude <2000m (prohibited to work in flammable and corrosive environment)

Detailed Photos

Relay Output Data Recorder ControlRelay Output Data Recorder ControlRelay Output Data Recorder Control


Product Showing

Relay Output Data Recorder ControlRelay Output Data Recorder ControlRelay Output Data Recorder ControlRelay Output Data Recorder Control


Certifications


Relay Output Data Recorder Control

Relay Output Data Recorder ControlRelay Output Data Recorder ControlRelay Output Data Recorder ControlRelay Output Data Recorder Control
FAQ

1. Q: Can I purchase any of your product accessories?

A: Absolutely! Most of our accessories are available for purchase. However, certain patented designs or items protected by intellectual property rights may not be available.
For more details, please contact our sales team.

2. Q: Can I become an exclusive distributor?

A: Yes, we welcome exclusive distributors. This depends on your annual purchase volume and long-term business relationship with us.
We seek trustworthy partners for a mutually beneficial long-term relationship.

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

From payment to delivery, we protect your trading.
Relay Output Data Recorder Control pictures & photos
Relay Output Data Recorder Control
US $108-240 / Piece
Min. Order: 1 Piece
Diamond Member Since 2023

Suppliers with verified business licenses

Secured Trading Service
Rating: 5.0/5
Trading Company
Number of Employees
16
Year of Establishment
2020-06-16