• Relay Output Temperature Recorder System
  • Relay Output Temperature Recorder System
  • Relay Output Temperature Recorder System
  • Relay Output Temperature Recorder System
  • Relay Output Temperature Recorder System
  • Relay Output Temperature Recorder System

Relay Output Temperature Recorder System

Display: Screen 128*64 DOT Matrix White Screen (LCD)
Weight: 0-100Kg
Processor: High-Performance Arm Cortex-M3 32-Bit Risc Core
Samples:
US$ 240/Piece 1 Piece(Min.Order)
| Order Sample
Customization:
Shipping Cost:

Estimated freight per unit.

about shipping cost and estimated delivery time.
Payment Method: visa mastercard discover JCB diners club american express T/T
  Initial Payment Full Payment
Currency: US$
Return&refunds: You can apply for a refund up to 30 days after receipt of the products.
From payment to delivery, we protect your trading.
Relay Output Temperature Recorder System pictures & photos
Relay Output Temperature Recorder System
US $108-240 / Piece
Min. Order: 1 Piece
Diamond Member Since 2023

Suppliers with verified business licenses

Secured Trading Service
Rating: 5.0/5
Trading Company
  • Overview
  • Product Description
  • Product Parameters
  • Detailed Photos
  • Product Showing
  • Certifications
  • FAQ
Overview

Basic Info.

Model NO.
GL-R2100E
Input Function
Support up to 4-Wire Analog Inputs
Output Function
Power Distribution, Variable Transmission, Relay a
Communication Function
Interface Provide RS232c and RS485, Modbus RTU
Power Supply
220VAC, 50Hz AC; 24VDC (18-36VDC), 12VDC (9-18VDC)
Accuracy
Thermocouple Cold End Comp. Error &Plusmn
Operating Environment1
Temperature 0-50ºC (Avoid Direct Sunlight)
Operating Environment2
Humidity 0-85%R.H. (No Condensation)
Meter Weight
≤1kg
Trademark
Aice Tech
Origin
China
HS Code
9026202000

Product Description

Welcome to the esteemed Jiangsu Aice Instrument Technology Co., Ltd., where innovation meets excellence.

Product Description

1. INTRODUCTION

Our Relay Output Temperature Recorder System is designed for versatile industrial applications. However, ensure to
provide separate protection for the device during unique applications.
Avoid operating in explosive atmospheres. Ensure proper ventilation at the installation site.
ventilate the installation site adequately.
Use the power supply at the rated voltage with correct wiring, proper grounding, and avoid touching the back terminals
to prevent electric shock.
To ensure safety, disconnect power during installation, maintenance, and removal.
maintenance, and removal processes.
It is essential to employ shielding measures when the device is near
environments with mains power, high electric fields, high magnetic fields, or AC contactors.
high magnetic fields, and AC contactors.
To avoid measurement errors when using a thermocouple sensor, employ the corresponding compensating wire,
and when using a thermal resistance sensor, use three identical copper conductors with a resistance below 10Ω.
when using a thermal resistance sensor, use three identical copper conductors with a resistance below 10Ω.
3. Product Parameters
Detailed Photos
Relay Output Temperature Recorder System

Product Parameters

Display
Screen
128*64 dot matrix white screen liquid crystal display (LCD)
Accuracy
Real-time display: ±0.2% F.S. Trace accuracy: ±0.2% F.S.
(Thermocouple should remove the cold end error)
Processor
Adopts high-performance ARM CORTEX-M3 32-bit RISC core
Input Functions
Input specifications
Supports up to 4 universal analog inputs
Voltage input
0-5V, 1-5V, 0-20MV, 0-100MV
Current input
0-10mA, 4-20mA, 0-20mA
Resistance input
RES (0-400Ω)
Thermistor
PT100, CU50, G53, CU100, BA1, BA2
Thermocouple
s, b, k, t, r, e, n, j
Radiation Pyrometer
F1, F2
Tungsten Rhenium
WRE3-25, WRE5-26
Note
Other input signals (e.g. 0-10V) or index numbers (e.g. PT1000) must be specified when ordering
Output Functions
Distribution output
Supports 1 channel for transmitter centralized power distribution +24VDC, power distribution <60mA
Transformer output
Support up to 2 channels of 4-20mA standard current transducer output, 500Ω load capacity (maximum), convenient for display
instrument or DCS/PLC acquisition, realize the long distance transmission of signal
Relay alarm output
Support up to 4 channels relay alarm output, contact capacity 3A@250VAC / 3A@30VDC, can be configured upper limit, upper limit,
lower limit, lower limit alarm.
Communication Function
Communication interface
RS232C and RS485 communication interface for user to choose, support MODBUS RTU protocol, baud rate (1200, 4800, 9600, 19200,
38400, 57600)
Printing interface
RS232C direct connection to micro printer, baud rate 1200
Power supply
220VAC, 50HZ AC power supply, support 24VDC (18-36VDC), support 12VDC (9-18VDC), Note: DC power supply should be specified when
ordering.
Accuracy
Thermocouple cold end compensation error ±2ºC
Clock error: 2 seconds / day
Working Environment
Ambient temperature
0-50°C (avoid e.g. direct sunlight)
Ambient humidity
0-85%R.H. (no condensation)
Altitude <2000m (prohibited to work in flammable and corrosive environment)

Detailed Photos

Relay Output Temperature Recorder SystemRelay Output Temperature Recorder SystemRelay Output Temperature Recorder System


Product Showing

Relay Output Temperature Recorder SystemRelay Output Temperature Recorder SystemRelay Output Temperature Recorder SystemRelay Output Temperature Recorder System


Certifications


Relay Output Temperature Recorder System

Relay Output Temperature Recorder SystemRelay Output Temperature Recorder SystemRelay Output Temperature Recorder SystemRelay Output Temperature Recorder System
FAQ

2. Q: Can I be your exclusive distributor?

A: Yes, potentially. This opportunity depends on your annual purchase volume and the prospect of building a long-term, trustworthy relationship.
We seek business partners committed to establishing enduring trust and collaboration with us.

3. Q: Can I get a sample before placing an order?

A: Certainly! We offer samples to help you evaluate our products before making a bulk purchase. Contact our sales team for further assistance.
A: Certainly! We offer samples to help you evaluate our products before making a bulk purchase. Contact our sales team for further assistance.

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

From payment to delivery, we protect your trading.
Relay Output Temperature Recorder System pictures & photos
Relay Output Temperature Recorder System
US $108-240 / Piece
Min. Order: 1 Piece
Diamond Member Since 2023

Suppliers with verified business licenses

Secured Trading Service
Rating: 5.0/5
Trading Company
Number of Employees
16
Year of Establishment
2020-06-16