• Advanced Doppler Ultrasonic Velocity Measuring Sensor
  • Advanced Doppler Ultrasonic Velocity Measuring Sensor
  • Advanced Doppler Ultrasonic Velocity Measuring Sensor
  • Advanced Doppler Ultrasonic Velocity Measuring Sensor
  • Advanced Doppler Ultrasonic Velocity Measuring Sensor
  • Advanced Doppler Ultrasonic Velocity Measuring Sensor

Advanced Doppler Ultrasonic Velocity Measuring Sensor

After-sales Service: 1 Year
Warranty: 1 Year
Accuracy: ±0.6-1%
Main Application: Water, Wastewater
Size: DN100-500
Sensor: Plug-in
Samples:
US$ 1905/Piece 1 Piece(Min.Order)
| Request Sample
Customization:
Diamond Member Since 2023

Suppliers with verified business licenses

Rating: 5.0/5
Trading Company
  • Overview
  • Product Description
  • Product Parameters
  • Detailed Photos
  • Installation Instructions
  • Certifications
  • FAQ
Overview

Basic Info.

Model NO.
RC-DP-101-C4
Application
Industrial Production
Type
Ultrasonic Flow Meter
Measuring Media
Liquid
Measuring Principle
Acoustics
Measurement Object
Open Channel
Certification
CE, ISO
Flow Rate Range
0~10m/S
Flow Rate Resolution
0.001m/S
Velocity Accuracy
0.001m/S (When Velocity <= 5m/S)
Ultrasonic Level Range
6.5m
Ultrasonic Level Accuracy
0.001m
Ultrasonic Level Resolution
0.0005m
Hydrostatic Level Range
0~10m
Hydrostatic Level Accuracy
±0.1%Fs
Hydrostatic Level Resolution
0.001m
Temperature Range
-20~60ºC
Install
Special Bracket
Material
Metal, POM, Rubber
Protection Class
IP68
Powered by
DC12V/24V
Power Consumption
<90mA During Measurement; <25mA During Sleep
Transport Package
Cartons
Specification
50*25*22CM 3KG
Trademark
Aice Tech
Origin
China
HS Code
9026100000
Production Capacity
5000000/Pieces

Product Description

Welcome to Jiangsu Aice Instrument Technology Co., Ltd., where innovation meets precision! As a frontrunner in the instrumentation industry, we are dedicated to providing state-of-the-art solutions tailored to your needs.

Product Description

The Acoustic Doppler Point Flowmeter is an innovative flow detection instrument designed specifically for rivers, open channels, and pipelines. Utilizing advanced ultrasonic detection technology, this device offers unparalleled high measurement accuracy and exceptional stability. Its performance remains uncompromised by environmental factors, thanks to its robust design that features no rotating parts, thereby significantly reducing maintenance needs. Whether for online or portable measurement, this flowmeter stands out as the preferred choice, ensuring high working reliability and consistent performance.

Leveraging the Doppler effect, this sensor expertly measures the frequency difference between transmission and reception to determine flow velocity. It also uses the time difference between ultrasonic transmission and reception to accurately gauge liquid levels. Designed to tackle even the most challenging working conditions, it incorporates static pressure level measurements and ambient temperature correction to ensure precise ultrasonic propagation speed. This multifaceted approach guarantees accurate and reliable readings in any environment.

Advanced Doppler Ultrasonic Velocity Measuring Sensor

Product Parameters

  • Flow rate range
    0~10m/s
    Flow rate resolution
    0.001m/s
    Velocity Accuracy
    0.001m/s (when velocity <= 5m/s); 0.02m/s or 0.3% of actual peak velocity (whichever is greater) (when velocity > 5m/s)
    Ultrasonic Level Range
    6.5m
    Ultrasonic Level Accuracy
    0.001m
    Ultrasonic level resolution
    0.0005m
    Hydrostatic level range
    0~10m
    Hydrostatic level accuracy
    ±0.1%FS
    Hydrostatic level resolution
    0.001m
    Temperature range
    -20~60ºC
    Install
    Special bracket
    material
    Metal, POM, Rubber
    Protection class
    IP68
    Powered by
    DC12V/24V
    Power consumption
    <90mA during measurement; <25mA during sleep
    Communication Interface
    RS485, Modbus
    Working temperature
    -20~60ºC
    Work pressure
    Max 6Bar
    Discover the unparalleled precision of Jiangsu Aice Instrument Technology Co., Ltd.'s Advanced Doppler Ultrasonic Velocity Measuring Sensor. Engineered for excellence, this cutting-edge sensor offers unmatched accuracy and reliability for all your velocity measurement needs.
Detailed Photos

Advanced Doppler Ultrasonic Velocity Measuring Sensor

Advanced Doppler Ultrasonic Velocity Measuring Sensor
Installation Instructions

Harnessing the Doppler effect, our sensor establishes a precise relationship between frequency differences during transmission and reception for accurate flow velocity measurement. It also utilizes time differences in ultrasonic transmission and reception to gauge liquid levels, with special provisions for static pressure levels under unique working conditions. Additionally, ambient temperature measurements ensure corrections for accurate ultrasonic propagation speeds.
1.1.2 CCharacteristics
Constructed from industrial-grade stainless steel and plastic, the sensor is waterproof, corrosion-resistant, and built to endure the toughest conditions.
Designed with no wearable parts, this sensor requires minimal maintenance, ensuring a low cost of ownership.
Delivers high resolution and exceptional measurement accuracy.
Engineered to last, the sensor boasts an impressive service life exceeding 5 years.
Unfazed by chemical reagents, varying liquid viscosities, and other potential interferences.
Effortless operation with an 18-key keypad and bilingual Chinese-English menu interface.
Provides a 4~20mA isolated current output for seamless integration.
Features an isolated RS485 (Modbus RTU) communication interface for reliable connectivity.
Equipped with upper and lower limit alarm function relay outputs for enhanced monitoring.

2.1 Installation Instructions
Follow these steps to ensure installer safety and optimal sensor performance:
:
1) Secure the meter box and sensor bracket in place.
2) Insert the meter head into the meter case and fasten securely.
3) Install the sensor in its designated position.
4) Complete the electrical connections as specified.

2.2 Mainframe Installation
The mainframe offers flexible installation options: either embedded or wall-mounted.
1) External dimensions of the mainframe: 176 x 150 x 86mm.

Advanced Doppler Ultrasonic Velocity Measuring Sensor

Wall mounting dimensions: 167 x 105mm.
Designed with four quick-mount wall holes, the product can be easily secured by fixing screws at the designated points and hanging the product accordingly.
Note: When installing the probe, ensure the product is fixed securely. Protect the instrument from direct sunlight and water exposure to extend its lifespan.
Advanced Doppler Ultrasonic Velocity Measuring Sensor

2.3 Sensor Installation
Precautions:
1) Handle the sensor with care to avoid shocks.
2) Do not unscrew the locking wire connector during installation to prevent sensor damage.
3) Ensure the water around the sensor does not freeze to avoid damage.
Sensor dimensions are as follows:
Advanced Doppler Ultrasonic Velocity Measuring Sensor

1) Follow these criteria to select an optimal sensor mounting location.
2) Position the sensor to ensure representative measurement results.
3) Install the sensor in an accessible location for regular maintenance and cleaning.
4) Position the sensor in a well-mixed process area without downtime, typically near the sampling point.
5) Install the sensor close to a representative sampling point within 1.5m (5 feet). During calibration and use, sample the process to compare instrument readings with lab analysis. Incorrect sampling can lead to erroneous comparisons.

2.4 Sensor Installation Method
Our versatile installation method involves immersing the Advanced Doppler Ultrasonic Velocity Measuring Sensor into the channel or pipeline using a mounting bracket. This technique is perfectly suited for a wide range of environments, including general open channels and diverse pipeline configurations.
For optimal performance, it is imperative to secure the sensor on the mounting bracket rather than suspend it by the sensor cable. Ensure the sensor is submerged at least 30cm below the water surface, or to the typical sampling depth, while also shielding it from direct, intense light to preserve accuracy.
1) Selection of Installation Site
Opt for locations where water flow is consistently smooth to achieve precise measurements.
In turbulent water conditions, the flow velocity readings often become erratic and unstable, leading to significant measurement errors. Therefore, it is crucial to avoid such areas for accurate results.
2) Upstream and Downstream Channel Specifications
Ideally, the sensor should be installed at a site where the upstream channel is at least 10 times the width of the channel in a straight line, and the downstream channel is 3 times the width in a straight line.
Advanced Doppler Ultrasonic Velocity Measuring Sensor

A longer straight upstream channel ensures smoother flow, resulting in velocity measurements that closely match the actual flow conditions. This section must be free of obstructions like gates or weirs to maintain a stable, turbulence-free water pattern ahead of the sensor.

Certifications


Advanced Doppler Ultrasonic Velocity Measuring Sensor

Advanced Doppler Ultrasonic Velocity Measuring SensorAdvanced Doppler Ultrasonic Velocity Measuring SensorAdvanced Doppler Ultrasonic Velocity Measuring SensorAdvanced Doppler Ultrasonic Velocity Measuring Sensor
FAQ

1. Q: Can I buy any of your product accessories?

A: Absolutely! You can purchase most of our accessories. However, please note that some patented designs or items covered by intellectual property rights may not be available for individual purchase.
For more detailed information, kindly reach out to our dedicated sales team.

2. Q: Can I be your exclusive distributor?

A: Yes, you can. However, this privilege is contingent upon your annual purchase volume and the establishment of a long-term, mutually trusting relationship.
We seek business partners who are committed to sustaining a long-lasting and trustworthy partnership.

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now