Welcome to Jiangsu Aice Instrument Technology Co., Ltd., where cutting-edge innovation meets unparalleled precision. Discover our industry-leading solutions designed to elevate your performance and accuracy.
-
Flow rate range
|
0~10m/s
|
Flow rate resolution
|
0.001m/s
|
Velocity Accuracy
|
0.001m/s (when velocity <= 5m/s); 0.02m/s or 0.3% of actual peak velocity (whichever is greater) (when velocity > 5m/s)
|
Ultrasonic Level Range
|
6.5m
|
Ultrasonic Level Accuracy
|
0.001m
|
Ultrasonic level resolution
|
0.0005m
|
Hydrostatic level range
|
0~10m
|
Hydrostatic level accuracy
|
±0.1%FS
|
Hydrostatic level resolution
|
0.001m
|
Temperature range
|
-20~60ºC
|
Install
|
Special bracket
|
material
|
Metal, POM, Rubber
|
Protection class
|
IP68
|
Powered by
|
DC12V/24V
|
Power consumption
|
<90mA during measurement; <25mA during sleep
|
Communication Interface
|
RS485, Modbus
|
Working temperature
|
-20~60ºC
|
Work pressure
|
Max 6Bar
|
Experience the cutting-edge technology with our High Precision Doppler Velocity Flow Sensor, meticulously crafted by Jiangsu Aice Instrument Technology Co., Ltd. Unparalleled accuracy and performance for your most demanding applications.
The Doppler effect is harnessed to establish a relationship between the frequency difference and flow velocity. Additionally, the time difference between ultrasonic transmission and reception is used to determine liquid levels. For specialized working conditions, static pressure level measurement is utilized. Ambient temperature is also measured to correct the actual speed of ultrasonic propagation, ensuring high precision and reliability.
1.1.2 CCharacteristics
Crafted from industrial stainless steel and robust industrial plastic, this sensor is designed to be waterproof, anti-corrosive, and exceptionally durable.
With no wearing parts, this sensor requires minimal maintenance and offers a low cost of ownership.
Delivers high resolution and superb measurement accuracy.
Boasting a sensor life of over 5 years, it ensures long-term reliability and performance.
Unaffected by chemical reagents, liquid viscosity, and other interfering factors, making it extremely versatile.
Features an 18-key keypad for easy operation and supports both Chinese and English menus.
Provides a 4~20mA isolated current output for versatile applications.
Equipped with an isolated RS485 (Modbus RTU) communication interface for seamless integration.
Includes a relay output for upper and lower limit alarm functions, enhancing safety and monitoring capabilities.
2.1 Installation Instructions
To ensure installer safety and sensor functionality, please adhere to the following installation steps:
:
1) Secure the meter box and sensor bracket in place.
2) Insert the meter head into the meter case and secure it firmly.
3) Install the sensor in its designated location.
4) Complete the electrical connections.
2.2 Mainframe Installation
The mainframe can be installed either embedded or wall-mounted.
1) External dimensions of the mainframe are 176 x 150 x 86mm.
Wall mounting dimensions are 167 x 105mm.
Designed with four quick wall mounting holes, simply align and fix the screws according to the wall mounting points, then hang the mainframe securely.
Note: Ensure the probe is fixed during British line commissioning. Protect the instrument from direct sunlight and water to extend its service life.
2.3 Sensor Installation
Precautions:
1) Avoid any shocks to the sensor!
2) Do not unscrew the locking wire connector on the sensor post-installation as it may cause damage.
3) Ensure the water around the sensor does not freeze to prevent damage.
Sensor dimensions are as shown:
1) Select a sensor mounting location adhering to the following criteria.
2) Mount the sensor at an optimal location in the process to obtain representative measurement results.
3) Install the sensor in an accessible location for regular cleaning.
4) Position the sensor where the process is well mixed and there is no downtime, ideally at the sampling point.
5) Install the sensor near a representative process sampling point, ensuring ease of sampling. The distance between the sensor and the sampling point should not exceed 1.5m (5 feet). During calibration and usage, compare instrument readings with laboratory results. Incorrect sampling can lead to erroneous comparison results.
2.4 Sensor Installation Method
The installation method involves immersing the High Precision Doppler Velocity Flow Sensor in the channel or pipe using the mounting bracket, making it ideal for general open channels, pipelines, and similar applications.
For optimal performance, the sensor must be securely attached to the mounting bracket. Hanging the sensor by its cable in water is strictly prohibited. Ensure the sensor is submerged to a depth of at least 30cm below the surface or to the standard sampling depth. Additionally, avoid direct exposure to intense light to maintain accuracy.
1) Choice of Installation Site
Select a location where the water flow is consistently smooth to obtain accurate measurements.
In regions where water flow is irregular and often turbulent, velocity measurements tend to be erratic and unstable, resulting in significant errors.
2) Requirements for Upstream and Downstream Channels
Ideally, the flowmeter's installation site should include an upstream channel with a width 10 times that of the straight channel, and a downstream channel width 3 times that of the straight channel.
The longer and straighter the upstream channel, the more consistent the water flow will be, leading to velocity measurements that closely reflect the actual flow. This section should be free from obstructions such as gates or weirs to ensure a smooth and turbulence-free flow pattern ahead of the sensor.



1. Q: Can I buy any of your product accessories?
A: Absolutely! While most of our accessories are available for purchase, please note that a few items with patented designs or under intellectual property constraints may not be available for sale.
For detailed information, kindly reach out to our dedicated sales team.
2. Q: Can I be your exclusive distributor?
A: Yes, indeed! However, this privilege depends on your annual purchase volume and the strength of our long-term relationship. We are seeking business partners who can cultivate a lasting relationship based on mutual trust.
We look forward to establishing a fruitful partnership with you.