• IP68 Ultrasonic Flow Rate Meter
  • IP68 Ultrasonic Flow Rate Meter
  • IP68 Ultrasonic Flow Rate Meter
  • IP68 Ultrasonic Flow Rate Meter
  • IP68 Ultrasonic Flow Rate Meter
  • IP68 Ultrasonic Flow Rate Meter

IP68 Ultrasonic Flow Rate Meter

After-sales Service: 1 Year
Warranty: 1 Year
Accuracy: ±0.6-1%
Main Application: Water, Wastewater
Size: DN100-500
Sensor: Plug-in
Samples:
US$ 1905/Piece 1 Piece(Min.Order)
| Request Sample
Customization:
Diamond Member Since 2023

Suppliers with verified business licenses

Rating: 5.0/5
Trading Company
  • Overview
  • Product Description
  • Product Parameters
  • Detailed Photos
  • Installation Instructions
  • Certifications
  • FAQ
Overview

Basic Info.

Model NO.
RC-DP-101-C4
Application
Industrial Production
Type
Ultrasonic Flow Meter
Measuring Media
Liquid
Measuring Principle
Acoustics
Measurement Object
Open Channel
Certification
CE, ISO
Flow Rate Range
0~10m/S
Flow Rate Resolution
0.001m/S
Velocity Accuracy
0.001m/S (When Velocity <= 5m/S)
Ultrasonic Level Range
6.5m
Ultrasonic Level Accuracy
0.001m
Ultrasonic Level Resolution
0.0005m
Hydrostatic Level Range
0~10m
Hydrostatic Level Accuracy
±0.1%Fs
Hydrostatic Level Resolution
0.001m
Temperature Range
-20~60ºC
Install
Special Bracket
Material
Metal, POM, Rubber
Protection Class
IP68
Powered by
DC12V/24V
Power Consumption
<90mA During Measurement; <25mA During Sleep
Transport Package
Cartons
Specification
50*25*22CM 3KG
Trademark
Aice Tech
Origin
China
HS Code
9026100000
Production Capacity
5000000/Pieces

Product Description

Welcome to the innovative world of Jiangsu Aice Instrument Technology Co., Ltd., where cutting-edge solutions meet unparalleled quality. Join us in exploring state-of-the-art technology designed to revolutionize the industry.

Product Description

The Acoustic Doppler Point Flowmeter is a cutting-edge flow detection instrument designed for rivers, open channels, and pipelines. Utilizing advanced ultrasonic detection technology, it offers unparalleled measurement accuracy and exceptional stability. Its operation is minimally affected by environmental variables, featuring no rotating parts, resulting in low maintenance needs and remarkable reliability. This makes it the premier choice for both online and portable flow measurement applications.

Harnessing the Doppler effect, this sophisticated instrument correlates the frequency difference between transmission and reception with flow velocity, and uses the time difference between ultrasonic transmission and reception to gauge liquid levels. It also employs static pressure level measurements for unique working conditions and ambient temperature readings to correct the actual speed of ultrasonic propagation, ensuring precise and reliable performance across various environments.

IP68 Ultrasonic Flow Rate Meter

Product Parameters

  • Flow rate range
    0~10m/s
    Flow rate resolution
    0.001m/s
    Velocity Accuracy
    0.001m/s (when velocity <= 5m/s); 0.02m/s or 0.3% of actual peak velocity (whichever is greater) (when velocity > 5m/s)
    Ultrasonic Level Range
    6.5m
    Ultrasonic Level Accuracy
    0.001m
    Ultrasonic level resolution
    0.0005m
    Hydrostatic level range
    0~10m
    Hydrostatic level accuracy
    ±0.1%FS
    Hydrostatic level resolution
    0.001m
    Temperature range
    -20~60ºC
    Install
    Special bracket
    material
    Metal, POM, Rubber
    Protection class
    IP68
    Powered by
    DC12V/24V
    Power consumption
    <90mA during measurement; <25mA during sleep
    Communication Interface
    RS485, Modbus
    Working temperature
    -20~60ºC
    Work pressure
    Max 6Bar
    Technical Specifications: Precision-engineered to deliver unparalleled accuracy in diverse fluid measurement applications, the IP68 Ultrasonic Flow Rate Meter stands as a hallmark of reliability and innovation.
Detailed Photos

IP68 Ultrasonic Flow Rate Meter

IP68 Ultrasonic Flow Rate Meter
Installation Instructions

Leveraging the Doppler effect, the IP68 Ultrasonic Flow Rate Meter utilizes the frequency difference between transmission and reception to correlate with flow velocity. Additionally, it employs the time difference between ultrasonic transmission and reception for liquid level assessment. For special working conditions, static pressure levels are measured, and ambient temperature measurements are performed to correct the actual speed of ultrasonic propagation.
1.1.2 CCharacteristics
Constructed from premium industrial stainless steel and robust industrial plastic, this product is waterproof, corrosion-resistant, and built for long-lasting durability.
Designed with no wearing parts, this meter requires minimal maintenance and ensures low operational costs.
Offers exceptional high resolution and superior measurement accuracy.
The sensor boasts an impressive service life exceeding 5 years.
Unmatched resistance to chemical reagents, liquid viscosity variations, and other interferences.
User-friendly 18-key keypad with bilingual Chinese and English menus.
Features a 4~20mA isolated current output for reliable performance.
Equipped with an isolated RS485 (Modbus RTU) communication interface for seamless integration.
Includes a relay output function for upper and lower limit alarms, enhancing safety.

2.1 Installation Instructions
To ensure installer safety and optimal sensor performance, please follow these step-by-step instructions carefully.
:
1) Begin by mounting the meter box and sensor bracket securely.
2) Fit the meter head into the meter case and ensure it is firmly secured.
3) Proceed to mount the sensor.
4) Finally, complete the electrical connections.

2.2 Mainframe Installation
The mainframe offers two installation options: embedded and wall-mounted.
1) External dimensions of the mainframe are 176 x 150 x 86mm.

IP68 Ultrasonic Flow Rate Meter

Wall mounting dimensions are 167 x 105mm.
Designed with four quick wall mounting holes for effortless installation. Simply secure the screws at the designated points and hang the product in place.
Note: Ensure the probe is securely fixed during commissioning. To prolong the instrument's lifespan, protect it from direct sunlight and water exposure.
IP68 Ultrasonic Flow Rate Meter

2.3 Sensor Installation
Precautions:
1) Avoid any shocks to the sensor to prevent damage.
2) Do not unscrew the locking wire connector on the sensor during installation to avoid potential damage.
3) Ensure the water around the sensor does not freeze, as this can harm the sensor.
Sensor dimensions are as specified:
IP68 Ultrasonic Flow Rate Meter

1) Select the sensor mounting location based on the following criteria.
2) Position the sensor appropriately in the process to ensure accurate and representative measurement results.
3) Install the sensor in an accessible location for regular cleaning and maintenance.
4) Place the sensor in a well-mixed area of the process with no downtime, usually near the sampling point.
5) Mount the sensor near a representative process sampling point. Ensure the location is convenient for operator sampling, with the sensor no more than 1.5m (5 feet) from the sampling point. Proper sampling is crucial for accurate comparisons between instrument readings and laboratory analysis.

2.4 Sensor Installation Method
The installation method involves immersing the sensor in the channel or pipe using a mounting bracket, making it ideal for general open channels, pipelines, and similar scenarios.
Ensure the sensor is securely installed on the mounting bracket. Do not suspend the sensor in the water using the cable. The sensor should be immersed to a depth of at least 30cm below the water surface, or to the depth typically reached during sampling, while avoiding direct exposure to strong light.
1) Choice of Installation Site
Select a location where the water flow is consistently smooth to ensure accurate measurements.
In areas where the water flow is not smooth and frequently turbulent, the measured flow velocity will be erratic and unstable, resulting in significant errors.
2) Requirements for Upstream and Downstream Channels
Ideally, the flowmeter installation site should have an upstream channel width of 10 times the straight channel and a downstream width of 3 times the straight channel.
IP68 Ultrasonic Flow Rate Meter

The longer and straighter the upstream channel, the smoother the flow, resulting in velocity measurements that closely match the actual flow. This section should be free of obstructions such as gates or weirs to ensure a smooth, turbulence-free flow pattern in front of the sensor.

Certifications


IP68 Ultrasonic Flow Rate Meter

IP68 Ultrasonic Flow Rate MeterIP68 Ultrasonic Flow Rate MeterIP68 Ultrasonic Flow Rate MeterIP68 Ultrasonic Flow Rate Meter
FAQ

1. Q: Can I buy any of your product accessories?

A: Yes, you can. Most accessories are available for purchase. However, in certain cases involving patented designs or protected intellectual property, they may not be available.
For more details, please reach out to our sales team.

2. Q: Can I be your exclusive distributor?

A: Absolutely! However, this depends on your annual purchase volume and our mutual long-term relationship. We seek business partners who can cultivate a lasting relationship rooted in trust.
We are committed to fostering a partnership built on long-term mutual trust.

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now