• Power Distribution Temperature Recorder Control
  • Power Distribution Temperature Recorder Control
  • Power Distribution Temperature Recorder Control
  • Power Distribution Temperature Recorder Control
  • Power Distribution Temperature Recorder Control
  • Power Distribution Temperature Recorder Control

Power Distribution Temperature Recorder Control

Display: Screen 128*64 DOT Matrix White Screen (LCD)
Weight: 0-100Kg
Processor: High-Performance Arm Cortex-M3 32-Bit Risc Core
Samples:
US$ 240/Piece 1 Piece(Min.Order)
| Order Sample
Customization:
Shipping Cost:

Estimated freight per unit.

about shipping cost and estimated delivery time.
Payment Method: visa mastercard discover JCB diners club american express T/T
  Initial Payment Full Payment
Currency: US$
Return&refunds: You can apply for a refund up to 30 days after receipt of the products.
From payment to delivery, we protect your trading.
Power Distribution Temperature Recorder Control pictures & photos
Power Distribution Temperature Recorder Control
US $108-240 / Piece
Min. Order: 1 Piece
Diamond Member Since 2023

Suppliers with verified business licenses

Secured Trading Service
Rating: 5.0/5
Trading Company
  • Overview
  • Product Description
  • Product Parameters
  • Detailed Photos
  • Product Showing
  • Certifications
  • FAQ
Overview

Basic Info.

Model NO.
GL-R2100E
Input Function
Support up to 4-Wire Analog Inputs
Output Function
Power Distribution, Variable Transmission, Relay a
Communication Function
Interface Provide RS232c and RS485, Modbus RTU
Power Supply
220VAC, 50Hz AC; 24VDC (18-36VDC), 12VDC (9-18VDC)
Accuracy
Thermocouple Cold End Comp. Error &Plusmn
Operating Environment1
Temperature 0-50ºC (Avoid Direct Sunlight)
Operating Environment2
Humidity 0-85%R.H. (No Condensation)
Meter Weight
≤1kg
Trademark
Aice Tech
Origin
China
HS Code
9026202000

Product Description

Welcome to Jiangsu Aice Instrument Technology Co., Ltd.

Product Description

1. INTRODUCTION

Our Power Distribution Temperature Recorder Control is meticulously designed for general industrial purposes. However, in specialized applications, please ensure proper protection of the device.
Ensure separate protection for the device in specialized applications, ensuring safety and efficiency.
Avoid operating in explosive atmospheres and always ensure adequate ventilation at the installation site.
Always provide proper ventilation at the installation site.
Use the rated voltage for the power supply, ensure correct wiring, proper grounding, and avoid touching the terminals on the back to prevent electric shocks.
Ensure correct wiring, proper grounding, and avoid touching the terminals on the back to prevent electric shocks.
To maintain safety, make sure the device is not charged during installation, maintenance, or removal.
Ensure the device is not charged during installation, maintenance, and removal to maintain safety.
Follow these safety steps diligently.
When the device is near mains power, high electric fields, high magnetic fields, or AC contactors, please take shielding measures.
Implement shielding measures near mains power, high electric fields, high magnetic fields, and AC contactors to avoid interference.
Shielding is essential to prevent interference and ensure accurate measurements.
To avoid measurement errors when the sensor is a thermocouple, use the corresponding compensating wire. If the sensor is a thermal resistance, use three identical copper conductors with resistance less than 10Ω.
Use corresponding compensating wire for thermocouples and identical copper conductors for thermal resistances with resistance under 10Ω to ensure measurement accuracy.
Accurate sensor wiring is crucial for precise measurements.
Accuracy is maintained with proper wiring practices.
Power Distribution Temperature Recorder Control

Product Parameters

Display
Screen
128*64 dot matrix white screen liquid crystal display (LCD)
Accuracy
Real-time display: ±0.2% F.S. Trace accuracy: ±0.2% F.S.
(Thermocouple should remove the cold end error)
Processor
Adopts high-performance ARM CORTEX-M3 32-bit RISC core
Input Functions
Input specifications
Supports up to 4 universal analog inputs
Voltage input
0-5V, 1-5V, 0-20MV, 0-100MV
Current input
0-10mA, 4-20mA, 0-20mA
Resistance input
RES (0-400Ω)
Thermistor
PT100, CU50, G53, CU100, BA1, BA2
Thermocouple
s, b, k, t, r, e, n, j
Radiation Pyrometer
F1, F2
Tungsten Rhenium
WRE3-25, WRE5-26
Note
Other input signals (e.g. 0-10V) or index numbers (e.g. PT1000) must be specified when ordering
Output Functions
Distribution output
Supports 1 channel for transmitter centralized power distribution +24VDC, power distribution <60mA
Transformer output
Support up to 2 channels of 4-20mA standard current transducer output, 500Ω load capacity (maximum), convenient for display
instrument or DCS/PLC acquisition, realize the long distance transmission of signal
Relay alarm output
Support up to 4 channels relay alarm output, contact capacity 3A@250VAC / 3A@30VDC, can be configured upper limit, upper limit,
lower limit, lower limit alarm.
Communication Function
Communication interface
RS232C and RS485 communication interface for user to choose, support MODBUS RTU protocol, baud rate (1200, 4800, 9600, 19200,
38400, 57600)
Printing interface
RS232C direct connection to micro printer, baud rate 1200
Power supply
220VAC, 50HZ AC power supply, support 24VDC (18-36VDC), support 12VDC (9-18VDC), Note: DC power supply should be specified when
ordering.
Accuracy
Thermocouple cold end compensation error ±2ºC
Clock error: 2 seconds / day
Working Environment
Ambient temperature
0-50°C (avoid e.g. direct sunlight)
Ambient humidity
0-85%R.H. (no condensation)
Altitude <2000m (prohibited to work in flammable and corrosive environment)

Detailed Photos

Power Distribution Temperature Recorder ControlPower Distribution Temperature Recorder ControlPower Distribution Temperature Recorder Control


Product Showing

Power Distribution Temperature Recorder ControlPower Distribution Temperature Recorder ControlPower Distribution Temperature Recorder ControlPower Distribution Temperature Recorder Control


Certifications


Power Distribution Temperature Recorder Control

Power Distribution Temperature Recorder ControlPower Distribution Temperature Recorder ControlPower Distribution Temperature Recorder ControlPower Distribution Temperature Recorder Control
FAQ

1. Q: Can I buy any of your product accessories?

A: Yes, you can purchase most of our product accessories. However, there are a few exceptions regarding patented designs or intellectual property. For more details, please contact our sales team.
Contact our sales team for more details on accessory availability.

2. Q: Can I be your exclusive distributor?

A: Yes, we welcome the opportunity to discuss exclusive distribution. This will depend on your annual purchase volume and the establishment of a long-term, trustworthy relationship.
We value long-term, trustworthy partnerships for exclusive distribution.

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

From payment to delivery, we protect your trading.
Power Distribution Temperature Recorder Control pictures & photos
Power Distribution Temperature Recorder Control
US $108-240 / Piece
Min. Order: 1 Piece
Diamond Member Since 2023

Suppliers with verified business licenses

Secured Trading Service
Rating: 5.0/5
Trading Company
Number of Employees
16
Year of Establishment
2020-06-16