• Economical Ultrasonic Water Flow Meter
  • Economical Ultrasonic Water Flow Meter
  • Economical Ultrasonic Water Flow Meter
  • Economical Ultrasonic Water Flow Meter
  • Economical Ultrasonic Water Flow Meter
  • Economical Ultrasonic Water Flow Meter

Economical Ultrasonic Water Flow Meter

Warranty: 12 Months
Accuracy: >±1%
Main Application: Wastewater
Sensor: Clamp-on/External
Application: Flow Meter
Type: Ultrasonic Flow Meter
Samples:
US$ 221/Piece 1 Piece(Min.Order)
| Request Sample
Customization:
Diamond Member Since 2023

Suppliers with verified business licenses

Rating: 5.0/5
Trading Company
  • Overview
  • Product Description
  • Product Parameters
  • Detailed Photos
  • Installation Instructions
  • Certifications
Overview

Basic Info.

Model NO.
RC-MQ201-C4
Measuring Media
Liquid
Certification
CE
Measuring Medium
Liquid Level
Measurement Method
Ultrasonic
Measurement Blind Area
0.3m
Measurement Accuracy
0.3%Fs
Power Supply
220VAC/ 24VDC
Discrimination Rate
1mm
Protection Level
Probe IP65
Instrument Power Consumption
5W
Trademark
Aice Tech
Origin
China
HS Code
9026202000

Product Description

Welcome to Jiangsu Aice Instrument Technology Co., Ltd., where innovation meets precision.

Product Description

1. INTRODUCTION

The Ultrasonic Open Channel Flowmeter from Jiangsu Aice Instrument Technology Co., Ltd. is a state-of-the-art, non-contact device that uses acoustic reflection principles to accurately measure water levels in weirs. This sophisticated meter, comprising an ultrasonic probe and a mainframe, is encased in a fully plastic-sealed structure, ensuring durability and reliability. Widely applicable in both industrial and environmental sectors, this flowmeter excels in detecting open channel flow with unparalleled accuracy. The ultrasonic probe, positioned above the weir, intermittently emits ultrasonic waves that reflect off the liquid surface. These reflections are captured by the probe, and the propagation time (t) is meticulously measured by the main unit. By identifying the type of weir, the host unit precisely calculates the flow rate based on the detected liquid level.
Economical Ultrasonic Water Flow Meter

Product Parameters

Cumulative flow range
0~9999999 (full 8 bits are cleared, the accumulated times are incremented by 1, and the flow unit is set according to the setting)
Instantaneous flow range
10L/s~100m3/s (determined by the type and specification of the weir tank)
Flow accuracy
5%
Blind distance
0.06-2m (depending on different sensors)
Range
Default 3m (customizable)
Probe material
ABS material
Protection class
IP65
Cable length
10m shielded cable (customizable)
Host performance
Chinese 3 o'clock LCD, 18-bit keyboard operation, M16*1.5 electrical interface
Power supply
AC85~380V, DC11~24V
Power consumption
5W
Input signal
Ultrasonic probe, RS485 serial port
Output signal
1 (standard) or 2 4-20mA, 4 relays, RS485
Sensor Mounting Interface
Standard 485 interface (24V power supply)*2
Data browsing
Quickly view hour, day, month, and year traffic records
Option function
Support U disk data export

Detailed Photos

Economical Ultrasonic Water Flow Meter

Economical Ultrasonic Water Flow Meter
Installation Instructions

Economical Ultrasonic Water Flow MeterEconomical Ultrasonic Water Flow Meter

Economical Ultrasonic Water Flow MeterEconomical Ultrasonic Water Flow Meter
I. Basic Setting After installing the instrument, simply configure the installation height and select the appropriate standard weir/flume type along with its corresponding instrument for seamless operation. II. Installation Height Setting The installation height varies depending on the type of water measuring weir/flume. Here’s a guide for confirming the installation height for several standard weir/flume types: Parshall Flume: Measure the vertical distance from the end of the ultrasonic transducer (probe) to the bottom inside the flume, in meters. Rectangular Weir: Measure the vertical distance from the end of the ultrasonic transducer (probe) to the lowest point of the water outlet, in meters. Triangular Weir: Measure the vertical distance from the end of the ultrasonic transducer (probe) to the right-angle point of the water outlet, in meters.
III. Flumes/Weirs Selection and Setting of Corresponding Geometric Parameters Select the standard flume/weir type based on the actual configuration. Adjust the geometric parameters accordingly. Here are the parameters for some common flume/weir types: Parshall Flume: Choose the flume type as Parshall Flume and set the standard flume number based on the throat section width, as indicated in Table 1. Rectangular Weir: Select the flume type as Rectangular Weir and configure the channel width, weir width, bottom height, and other geometric parameters.
Economical Ultrasonic Water Flow Meter


Certifications


Economical Ultrasonic Water Flow Meter

Economical Ultrasonic Water Flow MeterEconomical Ultrasonic Water Flow Meter

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now